English
Language : 

T-1228 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – IDSL PULSE TRANSFORMER
IDSL PULSE TRANSFORMER
Turns Ratio PRI : SEC ( + 2% )
PARAMETER
MIN
Inductance
13.32
Leakage Inductance
Interwinding Capacitance
DCR (ANY WINDING)
1.64CT : 1CT
MAX
UNITS
16.28
mH
50
µH
40
pF
0.75
Ω
SCHEMATIC DIAGRAM:
1
10
2
PRI
4
9
SEC
7
5
6
Isolation
2500
VRMS
Test Conditions:
Inductance tested at 0.1V, and 10 kHz
(Pins 1-5 with 2-4 shorted)
Leakage Inductance tested at 0.1V, and 100 kHz
(Pins 1-5 with 2-4 shorted & 6-7-9-10 shorted)
Interwinding Capacitance tested at 0.1V, and 100 kHz
-Designed to meet UL1950 requirements for
suplementary insulation (250V working voltage).
-Designed to accommodate Siemens PEB 24902, with
no DC current.
PHYSICAL DIMENSIONS All dimensions in inches (mm):
.560
(14.22)
MAX.
.550
(13.97)
MAX.
.495
(12.57)
MAX.
PIN POSITION GRID 0.100 (2.54)
HOLES FOR BOBBIN PINS
.100
(2.54)
TYP.
.210
(5.33)
TYP.
.400
(10.16)
TYP.
Pin Diameter is 0.025 (0.64)
10 9 8 7 6
Bottom
View
1 234 5
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-1228
CUST P/N:
NAME:
DATE: 4/16/99
SHEET: 1 OF 1
Rhombus
Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971