English
Language : 

T-1227 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – SDSL PULSE TRANSFORMER
SDSL PULSE TRANSFORMER
Turns Ratio PRI : SEC ( + 2% )
PARAMETER
MIN
Inductance
1.93
Leakage Inductance
DCR (ANY WINDING)
Isolation
2500
2CT : 1
MAX
UNITS
2.36
mH
11
µH
0.60
Ω
VRMS
SCHEMATIC DIAGRAM:
1
Pri.
2
4
Pri.
9
Sec.
7
5
Test Conditions:
Inductance tested at 0.1V, and 10 kHz
(Pins 1-5 with 2-4 shorted )
Leakage Inductance tested at 0.1V, and 100 kHz
(Pins 1-5 with 2-4 shorted & 6-7-9-10 shorted)
-Designed to meet UL1950 requirements for
suplementary insulation (250V working voltage).
-Designed to accommodate Brooktree (Rockwell)
BT8970 and RS8973, with no DC current.
PHYSICAL DIMENSIONS All dimensions in inches (mm):
.560
(14.22)
MAX.
.495
(12.57)
MAX.
.550
(13.97)
MAX.
PIN POSITION GRID 0.100 (2.54)
HOLES FOR BOBBIN PINS
.100
(2.54)
TYP.
.210
(5.33)
TYP.
.400
(10.16)
TYP.
Pin Diameter is 0.025 (0.64)
10 9 8 7 6
Bottom
View
1 234 5
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-1227
CUST P/N:
NAME:
DATE: 4/16/99
SHEET: 1 OF 1
Rhombus
Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971