English
Language : 

T-1202 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – 2 kW Transformer
2 kW Transformer P/N T-1202
Parameter
Inductance
Min.
(1-2)
Typ. Max. Units
275
µH
Primary 300 V @ 7 amps
Secondary 200V @ 5 Amps
Interwinding Capacitance
65
pF
DC Resistance
(1-2)
19.4
mΩ
(3-4)
22.4
mΩ
(5-6)
22.4
mΩ
Hi-Pot Pins (1-2) to (3-4) & (5-6) 1500
VRMS
Operating Frequency
78
kHz
Physical Dimensions
inches (mm)
Schematic Diagram
2
PRI
1
3
SEC
4
5
SEC
6
TURNS RATIO
1 : 0.66 : 0.66
(1-2: 4-3 : 6-5 )
NOTE: Start = Long Wire
Stop = Short Wire
65
43
1
2
Rhombus
Industries Inc.
Transformers & Magnetic Products
5/20/97
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971