English
Language : 

T-1171 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – CURRENT TRANSFORMER
CURRENT TRANSFORMER
Electrical Specifications at 25OC
Parameter
Inductance * Pins 4-6
DCR (4-6)
DCR (1-8)
Isolation
* Tested at 100 mV, 1 kHz
Turns Ratio = 50 : 1
Dimensions
inches (mm)
Min.
7.68
3000
Typ.
10.98
130
1.1
Max.
14.27
Units
mH
mΩ
mΩ
VAC
Schematic
Diagram
4
1
.551
(14.00)
TYP.
.413
(10.50)
MAX.
6
8
.294
(7.50)
TYP.
.443
(11.25)
TYP.
8
6
Bottom
View
1
4
Rhombus
Industries Inc.
Transformers & Magnetic Products
.551
(14.00)
MAX.
.294
(7.50)
TYP.
.197
(5.00)
TYP.
Flammability: Materials
used in the production of
these units meet require-
ments of UL94-VO and
IEC 695-2-2 needle flame
test.
RHOMBUS P/N: T-1171
CUST P/N:
NAME:
DATE: 9/12/98
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com