T-10221 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – T1/CEPT PULSE TRANSFORMER
T1/CEPT PULSE TRANSFORMER
UL 1459 Recognized
R
Turns Ratio ( + 5% )
PARAMETER
1Open Circuit Inductance
1Primary Leakage Inductance
1Secondary Leakage Inductance
1Interwinding Capacitance (CW/W)
Primary DC Resistance
Secondary DC Resistance
Isolation (HI-POT)
E.T.
1:0.5:0.5
MIN.
1.5
MAX.
0.3
0.4
18
0.7
0.5
1.5 Kv
16
UNITS
mHy
µHy
µHy
pF
ohms
ohms
VRMS
V-µS
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Temperature Characteristics:
-40o C 900 µH min. (40% drop in
inductance)
+85o C 1.7 mH min. (15% growth in
inductance)
Typical part:
2.0 mH @ +25o C
2.3 mH @ +85o C
1.2 mH @ -40o C
Parts shipped in anti-static
tubes. 50 pieces per tube
*Primary Pins 5-6. A center tap
can be formed by shorting pins
1+4 creating a 1:1CT Transformer.
1 Tested at 772 kHz & 100 mV
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
SCHEMATIC DIAGRAM:
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-10221
CUST P/N:
NAME:
DATE: 11/04/97
SHEET: 1 OF 1