English
Language : 

T-10210 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – T1/CEPT PULSE TRANSFORMER
T1/CEPT PULSE TRANSFORMER
UL 1459 Recognized R
Turns Ratio ( + 5% )
1CT:2CT
PARAMETER
MIN.
Open Circuit Inductance
1.2
Leakage Inductance
Interwinding Capacitance (CW/W)
Primary DC Resistance
Secondary DC Resistance
Isolation (HI-POT)
1.5 Kv
TEST CONDITIONS:
Oscillation Voltage = 20mV
Oscillation Frequency = 100.0 KHz
Inductance measured on Primary winding. Pins 1 - 5.
MAX.
0.55
30
0.7
1.1
UNITS
mH
µH
pF
ohms
ohms
VRMS
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Temperature Characteristics:
-40o C 700 µH min.
(40% drop in inductance)
+85o C 1.4 mH min.
(15% growth in inductance)
Typical part:
1.7 mH @ +25o C
2.0 mH @ +85o C
1.0 mH @ -40o C
Parts shipped in anti-static
tubes. 50 pieces per tube
PHYSICAL DIMENSIONS
All dimensions in inches (mm)
SCHEMATIC DIAGRAM
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-10210
CUST P/N:
NAME:
DATE: 1/24/94
SHEET: 1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971