English
Language : 

L-403 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – FILTER CHOKE
FILTER CHOKE
Electrical Specifications at 25OC
Parameter
Min.
1Inductance @60 Hz & 1 V
11
DCR
Rated Current, I
DC
2Insulation
1000
Operating Frequency
1 Inductance measured at full rated current
2 Winding to core.
Typ.
0.75
60
Max.
1
Units
mH
Ω
A
VRMS
Hz
Physical Dimensions
inches (mm)
1.5
(38)
1.25
(32) 1.4
(36)
High Current 60 Hz
Smoothing Choke
Designed for Low Voltage/
High Current D.C. Power
Supply filtering applications
Materials used in construction
of this component meet or
exceed UL Class B and can be
operated up to 1300 C
Schematic
Diagram
1.75
(44)
.075
(1.9)
.075
(1.9)
.60
(15) 1.1
(28)
.09
(2.3)
.09
(2.3)
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS P/N: L-403
CUST P/N:
DATE: 9/30/97
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com