English
Language : 

L-286_1 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – HDSL Common Mode Choke
HDSL Common Mode Choke
Electrical Specifications at 25OC
Parameter
Min.
Inductance
7.5
Leakage Inductance
DCR
Isolation
600
Typ.
Max. Units
12.5 mH
20
µH
1.5
Ω
VRMS
Test Conditions:
Inductance & Leakage Inductance tested at 20mVRMS and 20 kHz
Typical Impedance Curve
250
200
150
100
50
0
100
200
500
1000
2000
Frequency ( kHz )
Pin Position Grid 0.100"
Bobbin Terminations
Physical Dimensions
inches (mm)
Schematic
Diagram
PRI
SEC
Rhombus
Industries Inc.
Transformers & Magnetic Products

$
%
!
&
"
'
#

RHOMBUS P/N: L-286
CUST P/N:
DATE: 7/1/96
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971