English
Language : 

L-12247 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – POWER LINE CHOKE
POWER LINE CHOKE
(DRUM CORE STYLE)
Electrical Specifications at 25OC
Parameter
Min.
Typ.
Max.
Units
Inductance
I1
MAX
DCR
Lead Diameter
704
880
1056 µH
5.4
A
200
mΩ
.0320
(0.812)
inches
(mm)
Test Conditions:
Inductance tested at 100 mVRMS and 1 kHz
1. Current for 10% drop in Inductance
Applications
Power Amplifiers
Filters Power Supplies
SCR and Triac Controls
Speaker Crossover Networks
RFI Suppression
Dimensions in inches
D
C
B
G
F
E
Dim.
A
B
C
D
E
F
G
inches
0.955
0.975
0.187
0.126
0.760
0.750
0.060
High Saturation
Pre-Tinned Leads
Center hole for mechanical mounting
A
Leads are .0320 (#20 AWG)
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS P/N: L-12247
CUST P/N:
NAME:
DATE: 10/19/01
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971