Very Low Profile Tax Filters
Attenuates 12 or 16 kHz signals to
telco equipment by more than 25 dB.
Uses standard-value capacitor for either
12 or 16 kHz resonance
Designed to provide 25 dB minimum
attenuation at 12 or 16 kHz.
Electrical Specifications at 25O C
Part
Number
Inductance (1)
+5%
(mH)
D.C. Resistance
Max.
(Ω)
F-3551
2.58
14.0
F-3552
1.44
10.0
F-3553
7.96
28.0
F-3554
4.52
20.0
1. Tested at 10KHz and 100 mVRMS
D.C. Current
Max.
(mA)
70
90
70
90
Hi-Pot
Min.
(VAC)
1250
1250
1250
1250
Schematic
Diagram
1
5
Attenuates
12 or 16 kHz
12 kHz, Parallel L with C=68 nF
16 kHz, Parallel L with C=68 nF
12 kHz, Series L with C=22 nF
16 kHz, Series L with C=22 nF
} Optional
use as
Dual
Use of F-3551 inductor in a parallel LC
configuration followed by a F-3553 in a
series configuration to provide more
than 40 dB attenuation of tax pulse signals
Use of F-3552 inductor in a parallel LC
configuration followed by a F-3554 in a
series configuration to provide more
than 40 dB attenuation of tax pulse signals
Physical Dimensions
inches (mm)
.079
(2.00)
TYP.
.020
(0.50)
TYP.
6
5
7
4
.660
8
9
2 (16.76)
MAX.
10
1
.660
(16.76)
MAX.
.027
(0.69)
.768
(19.50)
Terminal #1 Indicator
.172
(4.37)
MAX.
.053
(1.35)
Specifications subject to change without notice.
Rhombus
Industries Inc.
For other values & Custom Designs, contact factory.
TAXFILTR - 10/98