ALPHA-TRX433S Datasheet, PDF (5/14 Pages) rfsolutions.ltd – The Alpha Modules are extremely cost effective but high performance radio modules.
ALPHA RF TRANSCEIVER
ALPHA-TRX433S
ALPHA-TRX915S
AC characteristic(Transmitter)
symbol parameter
Pout
Typical output power
Co
Output capacitance
(set by the automatic antenna
tuning circuit)
Qo
Quality factor of the output
capacitance
Lout
Output phase noise
BR
FSK bit rate
dffsk
FSK frequency deviation
remark
433MHz band
915MHz band
Selectable in 3 dB
steps
In low bands
In high bands
In low bands
In high bands
100 kHz from carrier
1 MHz from carrier
Programmable in 15
kHz steps
min
3
-2
Pmax-21
typical
5
0
max
Pmax
Unit
dbm
2
2.6
3.2 pf
2.1
2.7
3.3
13
15
17
8
10
12
-75 dbc/HZ
-85
256 kbps
15
240 kHZ
AC characteristic(Turn-on/Turnaround timings)
symbol
Tst
Ttx_rx_XTAL_ON
Trx_tx_XTAL_ON
parameter
Crystal oscillator startup
time
Transmitter - Receiver
turnover time
Receiver - Transmitter
turnover time
remark
min
Crystal ESR < 100
Synthesizer off, crystal oscillator
on
Synthesizer off, crystal oscillator
on
typical max Unit
5
ms
450
us
350
us
Ttx_rx_SYNT_ON Transmitter - Receiver Synthesizer on, crystal oscillator
425
turnover time
on
Trx_tx_SYNT_ON Receiver - Transmitter Synthesizer on, crystal oscillator
300
turnover time
on
Cxl
Crystal load capacitance Programmable in 0.5 pF steps, 8.5
tolerance+/- 10%
tPOR
Internal POR timeout
After Vdd has reached 90% of
final value
tPBt
Wake-up timer clock
Calibrated every 30 seconds
0.96
period
Cin, D
tr, f
Digital input apacitance
Digital output rise/fall
time
15pF pure capacitive load
us
us
16 pf
100 ms
1.05 ms
2
pf
10 ns
R F Solutions Ltd.,
Unit 21, Cliffe Industrial Estate,
Lewes, E. Sussex. BN8 6JL. England.
Email : sales@rfsolutions.co.uk http://www.rfsolutions.co.uk
Information contained in this document is believed to be accurate, however no representation or warranty is given and no liability is assumed by R.F. Solutions Ltd. with respect to the accuracy of
such information. Use of products as critical components in life support systems is not authorised except with express written approval from R.F. Solutions Ltd.
DSALPHA-TRX-6 Feb ‘11
©2009 RF Solutions Ltd.
Page 5