RT4/RT5: Electrical Characteristics
Ambient temp = 25°C unless otherwise stated.
Characteristic
Supply Voltage
Supply Current (Vcc=5V IN=1kHz)
Supply Current (Vcc=5V IN=DC GND)
Working Frequency
Frequency Tolerance
RF Output Power into 50Ω (Vcc=5V)
Harmonic Spurious Emissions
Input Voltage High
Time from Power on to data transmission
Data Rate
Operating Temperature
RTQ4: Electrical Characteristics
Ambient temp = 25°C unless otherwise stated.
Characteristic
Supply Voltage
Supply Current (Vcc=5V IN=1kHz)
Working Frequency
Frequency Tolerance
RF Output Power into 50Ω (Vcc=4V)
Harmonic Spurious Emissions
Input Voltage High
Power-Up
Data Rate
Operating Temperature
RT14: Electrical Characteristics
Ambient temp = 25°C unless otherwise stated.
Characteristic
Supply Voltage
Supply Current (Vcc=5V IN=1kHz)
Working Frequency
RF Output Power into 50Ω (Vcc=4V)
Harmonic Spurious Emissions
Input Voltage High
Data Rate
Operating Temperature
Min.
2
303.8
2
50
-25
Min.
1.9
-35
+5
0.7*Vcc
50
-25
Min.
2
+10
2
50
-25
Typ.
4
50
0
-30
10
Max.
14
433.92
+/-100
Vcc
9,600
+80
Dimensions
Vdc
mA
nA
MHz
KHz
dBm
dBc
V
µSec
Hz
°C
Typ.
12
868.35
+7
-50
Max.
5
+35
1
9,600
+80
Dimensions
Vdc
mA
MHz
KHz
dBm
dBc
V
mSec
Hz
°C
Typ.
8
433.92
+12
-55
Max.
9
Vcc
9,600
+80
Dimensions
Vdc
mA
MHz
dBm
dBc
V
Hz
°C
R. F. Solutions Ltd.,
Unit 21, Cliffe Industrial Estate,
South Street, Lewes,
E Sussex, BN8 6JL, England.
Tel +44 (0)1273 898 000. Fax +44 (0)1273 480 661.
Email: sales@rfsolutions.co.uk Web: http://www.rfsolutions.co.uk
DS013-7 Jan ’08
©2008 REG No 277 4001, ENGLAND.
Page 4