105-433F Datasheet, PDF (2/4 Pages) rfsolutions.ltd – REMOTE RECEIVER DECODERS
‘105’ SERIES REMOTE RECEIVER DECODERS
Connections
SW1
POWER LED
LEARN LED
BATT LOW LED
J7 INFRA-RED
HEADER
J3 J2
VR1
GND
Connector to
Expander
RLY
9
J14
N/O COMM N/C
LOW BATT
ANT
D8
F1
D7
D10
D9 T1
J4
RF RECEIVER / PAGER
MAINS
T RANSFORM ER
E NL
230Vac
Mains
J5
0V 12-30
Vdc
CH4
CH2
CH3
CH4
RLY 1
RLY 2
RLY 3
RLY 4
J9
J10
J11
J12
N/O COMM N/C
O/P1
N/O COMM N/C
O/P2
N/O COMM N/C
O/P3
N/O COMM N/C
O/P4
The
decoder
requires
either a
single
12-30 Vdc
supply or
240Vac
mains.
NOT BOTH!
Warning!
The unit is designed to be a fixed installation, which may be connected to a mains supply. Before removing
the cover ensure that the mains input supply is removed. Any operation of the product that involves removal
of the front cover should only be carried out by a competent person or qualified electrician.
Configuration the Outputs (Jumper Links J2, J3)
These links configure the operation of the digital outputs according to the table below.
NOTE: The link status is read only on power up, after changing the links please to remove and re-apply
power.
The system is supplied with relay(s) type OMRON GL5114P or equivalent.
Note: The user must ensure that the load connected does not overload the relay!
J2
Open
Open
Connected
Connected
J3
Open
Connected
Open
Connected
RL 1
Latch
Timed
Latch
Timed
RL 2
Latch
Momentary
Latch
Momentary
RL 3
Latch
Momentary
Momentary
Latch
RL 4
Latch
Momentary
Momentary
Latch
Latch:
The relay operates until the next valid transmission is received
Momentary: The relay operates momentarily, or for as long as the Tx encoder switch is held on.
Removing Timed Output: Turn the trimmer (VR1) fully Clockwise.
Timed Output (O/P1)
This is a variable timed output controlled by VR1. This may be adjusted from no delay to a maximum of 4
minutes 15 seconds. Turning VR1 anti-clockwise increases the output delay.
A timed output is triggered by a signal from the transmitter, subsequent signals from the transmitter will cancel
the timed output.
DS105-6 April ‘05
©2003 Reg. No. 227 4001, England
Page 2