6.2 Mechanical Details
SMART RADIO TRANSCEIVER
RF650
6.3 DIP Switch Configuration
DIP Switch
Name
1
PD (Power Down)
2,3
Data Rate
4
Configuration
5
RTS
6
CTS
Type
In
In
In
In
Out
Description
OFF : Power Down mode; ON : Operating mode.
Host Data Rate selection (see next table).
OFF : Configuration mode; ON : Operating mode.
OFF, OFF : RTS,CTS Disabled (RS232 without handshake);
ON, ON : RTS,CTS Enabled (RS232 with handshake).
6.3.1 Host Data Rate Selection
DR1 (SW2)
OFF
ON
OFF
ON
DR2 (SW3)
OFF
OFF
ON
ON
Baud Rate
4,800
9,600
19,200
38,400