English
Language : 

H1W200102 Datasheet, PDF (10/10 Pages) rfsolutions.ltd – Micro RWD H1 “Wiegand” Output Version
ib technology
Hitag 1 Configuration Bytes
The Hitag 1 transponder mode and whether the memory pages are locked or open for
read/write operations is controlled by the configuration bytes. These are bytes 0 and 1 of
Page 1 of the Hitag 1 memory. Note that bytes 2 and 3 of the configuration page are not used
and are currently available for read/write use.
Configuration Byte 0 (Page 1, byte 0)
b7 b6 b5 b4 b3 b2 b1 b0
11| | | | | |
| | | | | 0 = Block 7 read only
| | | | | 1 = Block 7 read/write
|||||
| | | | 0 = Block 6 read only
| | | | 1 = Block 6 read /write
||||
| | | 0 = Block 5 read only
| | | 1 = Block 5 read/write
|||
| | 0 = Block 4 read only
| | 1 = Block 4 read/write
||
| 0 = Block 3 read only
| 1 = Block 3 read/write (not used)
|
0 = Block 2 read only
1 = Block 2 read/write (not used)
Configuration Byte 1 (Page 1, byte 1)
b7 b6 b5 b4 b3 b2 b1 b0
| | | | | | |1
|||||||
| | | | | | Reserved
||||||
| | | | | Reserved
|||||
| | | | Reserved
||||
| | | 0 = Configuration (Page 1) read only
| | | 1 = Configuration (Page 1) read/write
|||
| | Reserved
||
| Reserved
|
Reserved
Note that these configuration bits are OTP. Once they are set to read-only the Hitag 1
transponder is hardware protected and they can never be changed.
Note that the “Reserved” bits of Configuration Byte 1 must not be altered. The current value
of byte 1 must be read first and the bits that can be changed, masked on before writing back.
No responsibility is taken for the method of integration or final use of Micro RWD
More information on the Micro RWD and other products can be found at the Internet web site:
http://www.ibtechnology.co.uk
Or alternatively contact IB Technology by email at:
sales@ibtechnology.co.uk
10