English
Language : 

RF6100-4 Datasheet, PDF (4/6 Pages) RF Micro Devices – 3V 1900MHZ LINEAR POWER AMPLIFIER
RF6100-4
Pin
1
2
3
4
5
6
7
8
9
10
Pkg
Base
Function
VCC1
RF IN
GND
VMODE
VREG
GND
GND
RF OUT
GND
VCC2
GND
Description
Interface Schematic
First stage collector supply. A low frequency decoupling capacitor
(e.g., 4.7µF) may be required.
RF input internally matched to 50Ω. This input is internally AC-coupled.
Ground connection. Connect to package base ground. For best perfor-
mance, keep traces physically short and connect immediately to
ground plane.
For nominal operation (High Power Mode), VMODE is set LOW. When
set HIGH, devices are biased lower to improve efficiency.
Regulated voltage supply for amplifier bias. In Power Down mode, both
VREG and VMODE need to be LOW (<0.5V).
Ground connection. Connect to package base ground. For best perfor-
mance, keep traces physically short and connect immediately to
ground plane.
Ground connection. Connect to package base ground. For best perfor-
mance, keep traces physically short and connect immediately to
ground plane.
RF Output internally matched to 50Ω. This output is internally
AC-coupled.
Ground connection. Connect to package base ground. For best perfor-
mance, keep traces physically short and connect immediately to
ground plane.
Output stage collector supply. A low frequency decoupling capacitor
(e.g., 4.7µF) is required.
Ground connection. The backside of the package should be soldered to
a top side ground pad which is connected to the ground plane with mul-
tiple vias. The pad should have a short thermal path to the ground
plane.
2-4