English
Language : 

RFRP3120 Datasheet, PDF (2/3 Pages) RF Micro Devices – 5MHz to 300MHz 35dB Reverse Hybrid (Low Current)
DRAFT
RFRP3120
DRAFT
Absolute Maximum Ratings
Parameter
RF Input Voltage (single tone)
DC Supply Over-Voltage (5 minutes)
Storage Temperature
Operating Mounting Base Temperature
Rating
65
30
-40 to +100
-30 to +100
Unit
dBmV
V
°C
°C
Caution! ESD sensitive device.
RoHS (Restriction of Hazardous
Substances): Compliant per EU Directive
2011/65/EU.
Nominal Operating Parameters
Exceeding any one or a combination of the Absolute
Maximum Rating conditions may cause permanent
damage to the device. Extended application of Absolute
Maximum Rating conditions to the device may reduce
device reliability. Specified typical performance or
functional operation of the device under Absolute
Maximum Rating conditions is not implied.
Parameter
Specification
Unit Condition
Min Typ Max
General Performance
VB = 24V; TMB = 30°C; ZS = ZL = 75Ω
Operating Frequency Range
5
300 MHz
Power Gain
34.5 35.2 35.5
34.3 35.8
dB f = 5MHz
dB f = 300MHz
Slope [1]
-0.2
0.6
1.2
dB f = 5MHz to 300MHz
Flatness of Frequency Response
±0.4 dB f = 5MHz to 300MHz
Input Return Loss
-20
dB f = 5MHz to 250MHz
Input Return Loss
-16
dB f = 250MHz to 300MHz
Output Return Loss
-20
dB f = 5MHz to 250MHz
Output Return Loss
-16
dB f = 250MHz to 300MHz
Noise Figure
5.1
5.5
dB f = 300MHz
Total Current Consumption (DC)
150.0 158.0 160.0 mA
Distortion data 5MHz to 300MHz
VB = 24V; TMB = 30°C; ZS = ZL = 75Ω
CTB
-70
dBc 7 ch. flat; VO = 50dBmV [2]
-62
-60
dBc 42 ch. flat; VO = 44dBmV [3]
XMOD
-63
dBc 7 ch. flat; VO = 50dBmV [2]
-60
-57
dBc 42 ch. flat; VO = 44dBmV [3]
CSO
-75
dBc 7 ch. flat; VO = 50dBmV [2]
-70
-62
dBc 42 ch. flat; VO = 44dBmV [3]
Notes:
1. The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency.
2. 7 channels, NTSC frequency raster: T7-T13 (7.0MHz to 43MHz), +50dBmV flat output level.
3. 42 channels, NTSC frequency raster: T7-T13 (7.0MHz to 43MHz), 2-6 (55.25MHz to 83.25MHz), A-W / 7-13 (121.25MHz to 295.25MHz), +44dBmV flat output
level.
Composite Second Order (CSO) - The CSO parameter (both sum and difference products) is defined by the NCTA. Composite Triple Beat (CTB) - The CTB parameter is
defined by the NCTA. Cross Modulation (XMOD) - Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the
carrier being tested.
DRAFT DRAFT RF Micro Devices Inc. 7628 Thorndike Road, Greensboro, NC 27409-9421
For sales or technical support, contact RFMD at +1.336.678.5570 or customerservice@rfmd.com.
DS130917
The information in this publication is believed to be accurate. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents or other rights of
third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended
application circuitry and specifications at any time without prior notice.
2 of 3