English
Language : 

RFDA3016 Datasheet, PDF (2/11 Pages) RF Micro Devices – Digital Controlled Variable Gain Amplifier 3000MHz to 3800MHz, 6-Bit 0.5dB LSB Control
RFDA3016
Absolute Maximum Ratings
Parameter
Supply Voltage
DC Supply Current
Rating
5.5
1000
Unit
VDC
mA
Caution! ESD sensitive device.
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
cause permanent damage to the device. Extended application of Absolute Maximum
Rating conditions to the device may reduce device reliability. Specified typical perfor-
mance or functional operation of the device under Absolute Maximum Rating condi-
tions is not implied.
Power Dissipation
Max RF Input Power for 50 Output Load
Operating Temperature (TCASE)
5.5
+24
-40 to +85
W
dBm
°C
The information in this publication is believed to be accurate and reliable. However, no
responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any
infringement of patents, or other rights of third parties, resulting from its use. No
license is granted by implication or otherwise under any patent or patent rights of
RFMD. RFMD reserves the right to change component circuitry, recommended appli-
cation circuitry and specifications at any time without prior notice.
Storage Temperature
Junction Temperature
ESD Rating (HBM)
-40 to +150
°C
+165*
°C
1000 (Class 1C)
V
RFMD Green: RoHS compliant per EU Directive 2002/95/EC, halogen free
per IEC 61249-2-21, < 1000ppm each of antimony trioxide in polymeric
materials and red phosphorus as a flame retardant, and <2% antimony in
solder.
Moisture Sensitivity Level
MSL3
*MTTF > 1E6 hours at 165°C junction temperature
Note: Operation of this device beyond any one of these limits may cause permanent damage.
Parameter
Overall
Frequency Range
Max Gain
Gain Control Range
Step Accuracy
P1dB
Output IP3
Control Interface
Settling Time
Noise Figure
Impedance
Input Return Loss
Output Return Loss
Total Supply Voltage
Supply Current
Thermal Resistance
Nominal Operating Parameters
Specification
Min. Typ. Max.
3000
3800
38
31.5
±(0.2 +15% attenuation setting)
30.4
34.6
40.5
6
250
4.8
50
19
11
4.75
5.0
5.25
250
30
Unit
Condition
MHz
dB
dB
dB
dBm
dBm
bit
ns
dB

dB
dB
V
mA
°C/W
Temp = 25°C, VCC= VDD = 5V, standard application circuit
Attenuation = 0dB, at 3500MHz
Major state error up to 3800MHz
Attenuation = 0dB, at 3500MHz
POUT = 10dBm/Tone, 1MHz spacing at 3500MHz, mini-
mum value occurs at low temperature
SPI Interface
tON, tOFF (10%/90% RF)
Attenuation = 0dB, 3500MHz
At 3500MHz
From VCC (SPI), VCC (AMP1), and VCC (AMP2)
Junction to backside of device
Typical RF Performance at Key Operating Frequencies
Parameter
Unit 3000MHz 3300MHz 3400MHz 3500MHz 3600MHz 3700MHz 3800MHz
Max Small Signal Gain
dB
36.6
37.6
38.0
38.1
37.9
37.3
36.0
Output P1dB
dBm
31.5
31.4
31.0
30.4
30.0
29.4
28.6
Output IP3*
dBm
36.3
39.4
39.4
40.5
40.8
41.5
41.1
Input Return Loss
dB
15.8
19.8
19.7
19.8
21.1
23.0
22.2
Output Return Loss
dB
12.6
10.7
10.6
11.2
12.4
13.1
12.1
Noise Figure
dB
4.8
4.8
4.8
4.8
4.9
5.0
5.0
*Note: OIP3 is tested at POUT = 10dBm/Tone and 1MHz spacing
2 of 11
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or customerservice@rfmd.com.
DS121126