English
Language : 

RF5373_1 Datasheet, PDF (2/14 Pages) RF Micro Devices – 1.8V TO 3.6V IEEE802.11b/g/n AND BLUETOOTH DRIVER/AMPLIFIER
RF5373
Absolute Maximum Ratings
Parameter
Supply Voltage
DC Supply Current
RF - Input Power
Operating Temperature
Storage Temperature
Moisture Sensitivity
ESD Human Body Model
(EIA/JESD22-114-A)
ESD Machine Model (EIA/JESD22-
115-A)
Rating
-0.5 to +3.6
90
15
-30 to +85
-40 to +100
JEDEC Level 3
600
100
Unit
V
mA
dBm
°C
°C
V
V
Caution! ESD sensitive device.
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
cause permanent damage to the device. Extended application of Absolute Maximum
Rating conditions to the device may reduce device reliability. Specified typical perfor-
mance or functional operation of the device under Absolute Maximum Rating condi-
tions is not implied.
RoHS status based on EUDirective2002/95/EC (at time of this document revision).
The information in this publication is believed to be accurate and reliable. However, no
responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any
infringement of patents, or other rights of third parties, resulting from its use. No
license is granted by implication or otherwise under any patent or patent rights of
RFMD. RFMD reserves the right to change component circuitry, recommended appli-
cation circuitry and specifications at any time without prior notice.
Parameter
IEEE802.11b
Frequency
Output Power
Gain
Gain Variance Over Temperature
-30°C to +85°C
Second Harmonic
802.11b Adjacent Channel Power
Alternate Channel Power
IEEE802.11b Spectral Mask per
FCC Part 15.205
Specification
Min.
Typ.
Max.
2.4
2.5
12
16
25
28
1.0
-27
-38
-32
-56
-52
-43
-43
Operating Current
Idle Current
IREG Current
Shutdown Current
Power Detector
POUT = +10 dBm
POUT = +12 dBm
Input Capacitance
Bandwidth
0.5
0.52
50
45
5.5
0.6
0.65
5
8
6.5
10
0.7
0.75
Unit
GHz
dBm
dB
±dB
dBm
dBc
dBc
dBm
dBm
mA
mA
mA
μA
V
V
pF
MHz
Condition
Nominal conditions: VCC=3.1V, VREG=1.75V,
Freq=2.45GHz, Temp=+25°C, unless other-
wise specified.
Meeting IEEE802.11b spectral mask require-
ments
2.4GHz to 2.5GHz
2.4GHz to 2.5GHz
Fundamental frequency is between 2400MHz
to 2500MHz (RFPOUT=+12dBm), see note 2
POUT=12dBm at nominal conditions
POUT=12dBm at nominal conditions
Amplifier setup for best IEEE802.11g perfor-
mance; FC=2412MHz; RFPOUT=+12dBm;
IEEE802.11b CCK 11Mbps modulation;
T=+25°C; measured at FC-25MHz
Amplifier setup for best IEEE802.11g perfor-
mance; FC=2462MHz; RFPOUT=+12dBm;
IEEE802.11b CCK 11Mbps modulation;
T=+25°C; measured at FC+25MHz
POUT=12dBm at nominal conditions
At nominal conditions with no RF
2 of 14
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
Rev A6 DS070521