D10040270GT
Nominal Operating Parameters
Parameter
Specification
Unit
Min Typ Max
Condition
General Performance
Power Gain
Slope[1]
Flatness of Frequency Response
Input Return Loss
Output Return Loss
Noise Figure
Total Current Consumption (DC)
V+ = 24V; TMB = 30°C; ZS = ZL = 75Ω
26.0 26.5 27.0 dB f = 50MHz
27.0 28.0 28.5 dB f = 1000MHz
0.5 1.5
2.0
dB f = 40MHz to 1000MHz
0.8 dB f = 40MHz to 1000MHz (Peak to Valley)
20.0
dB f = 40MHz to 320MHz
19.0
dB f = 320MHz to 640MHz
17.0
dB f = 640MHz to 870MHz
16.0
dB f = 870MHz to 1000MHz
20.0
dB f = 40MHz to 320MHz
19.0
dB f = 320MHz to 640MHz
18.0
dB f = 640MHz to 870MHz
17.0
dB f = 870MHz to 1000MHz
4.5
5.0
dB f = 50MHz to 1000MHz
360.0 375.0 mA
Distortion Data 40MHz to 870MHz
V+ = 24V; TMB = 30°C; ZS = ZL = 75Ω
CTB
-64 -62 dBc
XMOD
-60
-58 dBc 132 ch flat; V0 = 44dBmV[2]
CSO
-65 -63 dBc
1. The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency.
2. 132 channels, NTSC frequency raster: 55.25MHz to 865.25MHz, +44dBmV flat output level.
Composite Second Order (CSO) - The CSO parameter (both sum and difference products) is defined by the NCTA.
Composite Triple Beat (CTB) - The CTB parameter is defined by the NCTA.
Cross Modulation (XMOD) - Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the
carrier being tested.
RF Micro Devices Inc. 7628 Thorndike Road, Greensboro, NC 27409-9421
DS131220
For sales or technical support, contact RFMD at +1.336.678.5570 or customerservice@rfmd.com.
The information in this publication is believed to be accurate. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents or other rights of
third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended
application circuitry and specifications at any time without prior notice.
2 of 3