English
Language : 

TR1001 Datasheet, PDF (1/12 Pages) RF Monolithics, Inc – 868.35 MHz Hybrid Transceiver
®
• Designed for Short-Range Wireless Data Communications
• Supports RF Data Transmission Rates Up to 115.2 kbps
• 3 V, Low Current Operation plus Sleep Mode
• Stable, Easy to Use, Low External Parts Count
• Complies with Directive 2002/95/EC (RoHS)
The TR1001 hybrid transceiver is ideal for short-range wireless data applications where robust operation,
small size, low power consumption and low cost are required. The TR1001 employs RFM’s amplifier-se-
quenced hybrid (ASH) architecture to achieve this unique blend of character- istics. All critical RF functions
are contained in the hybrid, simplifying and speeding design-in. The receiver section of the TR1001 is sensi-
tive and stable. A wide dynamic range log detector, in combination with digital AGC and a compound data
slicer, provide robust performance in the presence of on-channel interference or noise. Two stages of SAW
filtering provide excellent receiver out-of-band rejection. The transmitter includes provisions for both on-off
keyed (OOK) and amplitude-shift keyed (ASK) modulation. The transmitter employs SAW filtering to suppress
output harmonics, facilitating compliance with ETSI I-ETS 300 220 and similar regulations.
TR1001
868.35 MHz
Hybrid
Transceiver
Rating
Power Supply and All Input/Output Pins
Non-Operating Case Temperature
Soldering Temperature (10 seconds / 5 cycles max.)
Value
-0.3 to +4.0
-50 to +100
260
Units
V
°C
°C
SM-20H Case
Electrical Characteristics
Characteristic
Operating Frequency
Modulation Types
OOK Data Rate
ASK Data Rate
Receiver Performance, High Sensitivity Mode
Sensitivity, 2.4 kbps, 10-3 BER, AM Test Method
Sensitivity, 2.4 kbps, 10-3 BER, Pulse Test Method
Current, 2.4 kbps (RPR = 330 K)
Sensitivity, 19.2 kbps, 10-3 BER, AM Test Method
Sensitivity, 19.2 kbps, 10-3 BER, Pulse Test Method
Current, 19.2 kbps (RPR = 330 K)
Sensitivity, 115.2 kbps, 10-3 BER, AM Test Method
Sensitivity, 115.2 kbps, 10-3 BER, Pulse Test Method
Current, 115.2 kbps
Receiver Performance, Low Current Mode
Sensitivity, 2.4 kbps, 10-3 BER, AM Test Method
Sensitivity, 2.4 kbps, 10-3 BER, Pulse Test Method
Current, 2.4 kbps (RPR = 1100 K)
Receiver Out-of-Band Rejection, ±5% fo
Receiver Ultimate Rejection
Sym
fo
R±5%
RULT
Notes
Minimum
868.15
Typical
OOK & ASK
Maximum
868.55
Units
MHz
30
115.2
kbps
kbps
1
-106
dBm
1
-100
dBm
2
3.0
mA
1
-101
dBm
1
-95
dBm
2
3.1
mA
1
-97
dBm
1
-91
dBm
3.8
mA
1
-104
dBm
1
-98
dBm
2
1.8
mA
3
80
dB
3
100
dB
RF Monolithics, Inc. Phone: (972) 233-2903
Fax: (972) 387-8148
RFM Europe
Phone: 44 1963 251383
Fax: 44 1963 251510
©1999 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
E-mail: info@rfm.com
http://www.rfm.com
TR1001-070105
Page 1 of 12