English
Language : 

SF2026B Datasheet, PDF (1/6 Pages) RF Monolithics, Inc – Low Insertion Loss
®
• Low Insertion Loss
• 5.0 X 7.0 mm Surface-Mount Case
• Complies with Directive 2002/95/EC (RoHS) Pb
SF2026B
114.815 MHz
SAW Filter
Absolute Maximum Ratings
Rating
Maximum Incident Power in Passband
Max. DC voltage between any 2 terminals
Storage Temperature Range
Suitable for lead-free soldering - Max Soldering Temperature
Value
Units
+10
dBm
0
VDC
-60 to +95
°C
260°C for 30 s
Electrical Characteristics
SMP-03
Characteristic
Center Frequency of IF SAW Filter (RF LO ±50ppm correction to 1st IF)
Insertion Loss
Amplitude Ripple (p-p) between 111.7594.......113.4107 MHz
(BW=1.64 MHz ±50ppm)
Amplitude Ripple (p-p) between 113.5993.......115.2508 MHz
(BW=1.64 MHz ±50ppm)
Amplitude Ripple (p-p) between 115.3492.......117.8709 MHz
(BW=1.64 MHz ±50ppm)
Pass Bandwidth of -1.5 dB
Pass Bandwidth of -3 dB
Low side attenuation 80 MHz...102.815 MHz (Fc -12 MHz)
Low side attenuation 102.815 MHz...107.690 MHz (Fc -7.125 MHz)
Low side attenuation 107.690 MHz...109.690 MHz (Fc -5.125 MHz)
High side attenuation 121.260 (Fc +6.445 MHz)...123.860 MHz (Fc +9.045 MHz)
High side attenuation 123.860 MHz...126.815 MHz (Fc +12.00 MHz)
High side attenuation 126.815 MHz...150.815 MHz (Fc +36.00 MHz)
Group Delay Ripple (p-p) between 111.7594.......113.4107 MHz
(BW=1.64 MHz ±50 ppm)
Group Delay Ripple (p-p) between 113.5993.......115.2508 MHz
(BW=1.64 MHz ±50 ppm)
Group Delay Ripple (p-p) between 115.3492.......117.8709 MHz
(BW=2.510 MHz ±50 ppm)
Operating Temperature Range
Case Style
Lid Symbolization (YY=year, WW=week, S=shift) See note 4
Sym
fC
IL
TA
Notes
1
1
6
Min
Typ
Max
114.815
12.5
15
1.3
Units
MHz
dB
1.3
dB
1.3
6.30
7.24
38
40
36
38
28
30
25
27
36
38
38
40
MHz
dB
80
ns
80
ns
100
ns
-40
+85
°C
SMP-03 7 x 5 mm Nominal Footprint
RFM SF2026B YYWWS
Notes:
1. Unless noted otherwise, all specifications apply over the operating temperature
range with filter soldered to the specified demonstration board with impedance
matching to 50 Ω and measured with 50 Ω network analyzer.
2. Unless noted otherwise, all frequency specifications are referenced to the nom-
inal center frequency, fc.
3. Rejection is measured as attenuation below the minimum IL point in the pass-
band. Rejection in final user application is dependent on PCB layout and exter-
nal impedance matching design. See Application Note No. 42 for details.
4. "LRIP" or "L" after the part number indicates "low rate initial production" and
"ENG" or "E" indicates "engineering prototypes."
5. The design, manufacturing process, and specifications of this filter are subject
to change.
6. Tape and Reel Standard Per ANSI / EIA 481.
7. Either Port 1 or Port 2 may be used for either input or output in the design.
However, impedances and impedance matching may vary between Port 1 and
Port 2, so that the filter must always be installed in one direction per the circuit
design.
8. US and international patents may apply.
9. RFM, stylized RFM logo, and RF Monolithics, Inc. are registered trademarks of
RF Monolithics, Inc.
10. ©Copyright 1999, RF Monolithics Inc.
11. Electrostatic Sensitive Device. Observe precautions for handling.
J = 50 Ohms
J = 50 Ohms
RF Monolithics, Inc. Phone: (972) 233-2903
Fax: (972) 387-8148
RFM Europe
Phone: 44 1963 251383
Fax: 44 1963 251510
©1999 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
E-mail: info@rfm.com
http://www.rfm.com
SF2026B-060305
Page 1 of 6