English
Language : 

SF1111A Datasheet, PDF (1/7 Pages) RF Monolithics, Inc – 160 MHz SAW Filter
Preliminary
• Designed for CDMA2000 BTS Applications
• Simple External Impedance Matching
• Hermetic SMP-97 Surface-Mount Case
• Unbalanced Input and Output
• Complies with Directive 2002/95/EC (RoHS)
Absolute Maximum Ratings
Rating
Maximum Incident Power in Passband
Max. DC voltage between any 2 terminals
Storage Temperature Range
Suitable for lead-free soldering - Max. Soldering Profile
Pb
Value
Units
+10
dBm
30
VDC
-40 to +85
°C
260°C for 30 s
Electrical Characteristics
Characteristic
Nominal Center Frequency
Passband
Insertion Loss at fc
1.5 dB Passband
3 db Passband
Amplitude Ripple over fc±470 kHz
Phase Linearity over fc ±590 kHz
Rejection
fc-10.0 to fc-1.25 and fc+1.25 to fc+10.0 MHz
fc-20 to fc-10.0 and fc+10.0 to fc+20 MHz
Operating Temperature Range
Sym
fC
IL
BW1.5
BW3
TA
Notes
1
1, 2
1, 2, 3
1
Min
±590
40
50
-20
SF1111A
160 MHz
SAW Filter
SMP-97
Typ
Max
160.000
9
11.0
±750
0.7
1.0
2
5
+70
Units
MHz
dB
kHz
dB
°rms
dB
°C
Impedance Matching to 50 Ω Unbalanced
Case Style
Lid Symbolization (YY = year, WW = week)
External L-C
SMP-97 24.6 x 9 mm Nominal Footprint
RFM SF1111A YYWW
Notes:
1. Unless noted otherwise, all specifications apply over the operating temperature range
with filter soldered to the specified demonstration board with impedance matching to 50 Ω
and measured with 50 Ω network analyzer.
2. Unless noted otherwise, all frequency specifications are referenced to the nominal center
frequency, fc.
3. Rejection is measured as attenuation below the minimum IL point in the passband.
Rejection in final user application is dependent on PCB layout and external impedance
matching design. See Application Note No. 42 for details.
4. "LRIP" or "L" after the part number indicates "low rate initial production" and "ENG" or "E"
indicates "engineering prototypes."
5. The design, manufacturing process, and specifications of this filter are subject to change.
6. Either Port 1 or Port 2 may be used for either input or output in the design. However,
impedances and impedance matching may vary between Port 1 and Port 2, so that the fil-
ter must always be installed in one direction per the circuit design.
7. US and international patents may apply.
8. Electrostatic Sensitive Device. Observe precautions for handling.
Electrical Connections
Connection
Port 1 Hot
Port 1 Gnd Return
Port 2 Hot
Port 2 Gnd Return
Case Ground
Terminals
10
1
5
6
All others
RF Monolithics, Inc. Phone: (972) 233-2903
Fax: (972) 387-9148
RFM Europe
Phone: 44 1963 251383
Fax: 44 1963 251510
©2001 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
E-mail: info@rfm.com
http://www.rfm.com
SF1111A-121504
Page 1 of 3