Absolute Maximum Ratings
Rating
Maximum Incident Power in Passband
Max. DC voltage between any 2 terminals
Storage Temperature Range
Suitable for lead-free soldering - Max. Soldering Profile
Value
Units
+18
dBm
30
VDC
-40 to +85
°C
260°C for 30 s
Electrical Characteristics
Characteristic
Nominal Center Frequency
Passband
Insertion Loss at fc
1 dB Passband
Amplitude Ripple over fc±100 kHz
Group Delay Variation over fc ±100 kHz
Rejection
fc-800 to fc-600 and fc+600 to fc+800 kHz
119 MHz to fc-800 kHz
fc+800 kHz to 278 MHz
Operating Temperature Range
Frequency Temperature Coefficient
Sym
fC
IL
BW1
GDV
TA
FTC
Notes
1
1, 2
1, 2, 3
1
1
Min
±100
35
45
45
-10
SF1092A
199 MHz
SAW Filter
SMP-75
Typ
199.000
5.5
±140
300
Max
7.0
1.0
500
Units
MHz
dB
kHz
dBP-P
nsP-P
dB
0.32
+85
°C
ppm/°C2
Impedance Matching to 50 Ω unbalanced
Case Style
Lid Symbolization (YY = year, WW = week)
External L-C
SMP-75 19 x 6.5 mm Nominal Footprint
RFM SF1092A YYWW
Notes:
1. Unless noted otherwise, all specifications apply over the operating temperature range with filter
soldered to the specified demonstration board with impedance matching to 50 Ω and measured
with 50 Ω network analyzer.
2. Unless noted otherwise, all frequency specifications are referenced to the nominal center fre-
quency, fc.
3. Rejection is measured as attenuation below the minimum IL point in the passband. Rejection
in final user application is dependent on PCB layout and external impedance matching design.
See Application Note No. 42 for details.
4. The turnover temperature, TO, is the temperature of maximum (or turnover) frequency, fo. The
nominal frequency at any case temperature, Tc, may be calculated from: f=fo[1-FTC(To-Tc)2].
5. The design, manufacturing process, and specifications of this filter are subject to change.
6. Either Port 1 or Port 2 may be used for either input or output in the design. However, imped-
ances and impedance matching may vary between Port 1 and Port 2, so that the filter must
always be installed in one direction per the circuit design.
7. US and international patents may apply.
8. Electrostatic Sensitive Device. Observe precautions for handling.
Electrical Connections
Connection
Port 1 Hot
Port 1 Gnd Return
Port 2 Hot
Port 2 Gnd Return
Case Ground
Terminals
10
1
5
6
All others
RF Monolithics, Inc. Phone: (972) 233-2903
Fax: (972) 387-8148
RFM Europe
Phone: 44 1963 251383
Fax: 44 1963 251510
©2001 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
E-mail: info@rfm.com
http://www.rfm.com
SF1092A-100605
Page 1 of 9