English
Language : 

RWP15020-10 Datasheet, PDF (4/5 Pages) RFHIC – Wideband Power Amplifier
Wideband Power Amplifier RWP15020-10
Precautions
1. This product is designed to be used for broadband amplification.
Heat generation is higher when there is no RF signal in the device. Therefore, the worst case scenario is when there is no
RF signal, and the amplifier is “on” with current draw. The temperature must be calculated properly.
Case temperature must maintain below 85°C.
2. Thermal Grease or Metal Thermal Interface Materials are recommended for heat dissipation.
An example would be spreading thermal grease on the bottom of the device.
Package Dimensions (Type: DP-75)
(Unit : mm/[inch], Tolerance : ±0.2/[.008])
20
[.787]
70
[2.756]
60
[2.362]
20
[.787]
38
[1.496] 15.6
50.8
[.616]
[2]
45
[1.772]
6.2
[.245]
6.9
[.273]
C
1
[.039]
17.1
[.673]
1.5
[.059]
7.3
[.288]
7.3
[.286]
6.9
[.273]
3.8
[.15]
5
[.197]
4.1
[.161]
38
[1.496]
50.8
[2]
70
[2.756]
60
[2.362]
'A'
3
[.12]
2.5
[.096]
2.7
[.106]
1.5
[.059]
How to connect the amplifier to a target PCB
Method-І (with Pin)
Method-ΙІ (without Pin) - If you cut out the pin
▪ Tel : 82-31-250-5011
▪ rfsales@rfhic.com
▪ All specifications may change without notice.
▪ Version 1.0