English
Language : 

RWP05040-10 Datasheet, PDF (4/6 Pages) RFHIC – Wideband Power Amplifier
Wideband Power Amplifier RWP05040-10
Input Return Loss
Output Return Loss
Precautions
1. This product is designed to be used for broadband amplification.
Heat generation is higher when there is no RF signal in the
device. Therefore, the worst case scenario is when there is
no RF signal, and the amplifier is “on” with current draw.
The temperature must be calculated properly.
Case temperature must maintain below 85°C.
Right side drawing notes how to use a temperature monitoring
function to protect against overheating.
2. Thermal Grease or Metal Thermal Interface Materials are
recommended for heat dissipation. An example would be spreading
thermal grease on the bottom of the device.
RF IN
Vcc(+28V)
Shut Down
(+5V)
RF OUT
Temp Monitor
Switch ON/OFF
+5V
+
-
Ref Voltage (+1.25V@85℃)
Comparator Block
▪ Tel : 82-31-250-5011
▪ rfsales@rfhic.com
▪ All specifications may change without notice.
▪ Version 2.0