English
Language : 

HCZ-H6 Datasheet, PDF (1/2 Pages) RFE international – HUMIDITY SENSOR
HUMIDITY SENSOR
HCZ-H6
INTRODUCTION
The HCZ-H6 humidity sensor is a
discreet device that can be installed
in a wide variety of applications.
APPLICATIONS
•Airconditioner, Humidifier, Dehumidifier
•Humidity Controller, Humidity transmitter
•Hygrometer, Hygro-recorder
•Copy machines, Data Equipment
•Appliance
•Weather forecast Equipment
DIMENSIONS
9
4
15
12
0.5
0.25
+/-2
2.5
2
FEATURES
•Wide humidity range
•Linear output
•Long term stability
•Small and economical
•RoHS Compliant
PART Number
HCZ - H6 A
1 23
1. Series
2. Dip type +/- 3%RH
3. A= Molded Body
B= Open Frame (unprotected)
element
ELECTRICAL CHARACTERISTICS
UNITS MIN. TYP. MAX.
Rated Voltage
Vrms
-
1
-
Rated power
mW
-
-
0.2
Operating frequency range
KHz
0.5
1
2
Operating temperature range
°C
0
-
60
Operating humidity range
%RH
-
-
90
Impedance range at 60%RH and 25°C** K¿
22.9
-
41.9
Humidity accuracy
%RH -3
-
+3
Hysteresis (40%RH~80%RH)
%RH
-
-
2
Temperature dependence (reference) %RH/°C -
0.6
-
**Measurement by LCR meter at 1KHz, 1 Vrms (sine wave)
Relative humidity (Impedance at 25°C, 1KHz, 1Vrms)
%RH
Impedance (K¿)
20
30 40 50 60 70 80 90
6,300 1,400 310 87 31 12 5.4 2.3
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail Sales@rfeinc.com
C7B01
REV2006.09.13