English
Language : 

FRH080-250UF Datasheet, PDF (1/2 Pages) RFE international – Radial Leaded PPTC FRH Series
Radial Leaded PPTC
RoHS
FRH Series
ü
FEATURES
•Low hold current, Solid state Radial-leaded product ideal for
up to 60V/250V/600V
•Application: Telecommunication and Data transmitting
•Operation Current: 0.08A ~ 0.18A
•Maximum Voltage: 60V/250V/600V
•Temperature Range: -40°C to 85°C
AGENCY RECOGNITION
•UL (E211981)
•C-UL (E211981)
•TÜV (R50004084)
ELECTRICAL CHARACTERISTICS (23°C)
Part Number
FRH080-250UF
FRH080-250F
FRH110-250UF
FRH110-250F
FRH120-250UF
FRH120-250F
FRH145-250UF
FRH145-250F
FRH180-250UF
FRH180-250F
FRH150-600F
FRH160-600F
Hold
Current
IH, A
0.08
0.08
0.11
0.11
0.12
0.12
0.15
0.15
0.18
0.18
0.15
0.16
Trip
Current
IT, A
0.16
0.16
0.22
0.22
0.24
0.24
0.29
0.29
0.65
0.65
0.30
0.32
Max. Time Maximum
to Trip Current
A Sec IMAX, A
0.35 4.0 3.0
0.35 4.0 3.0
1.0 2.0 3.0
1.0 2.0 3.0
1.0 2.0 3.0
1.0 2.0 3.0
1.0 2.5 3.0
1.0 2.5 3.0
1.5 10.0 10.0
1.5 11.0 10.0
1.0 5.0 3.0
1.0 7.0 3.0
Max. Oper.
Voltage
VMAX, VDC
60
60
60
60
60
60
60
60
60
60
60
60
Max. Int.
Voltage
VI-MAX, V
250
250
250
250
250
250
250
250
250
250
600
600
Resistance Tolerance
RMIN
R1MAX
OHMS OHMS
14.0
33.0
14.0
33.0
5.0
16.0
5.0
16.0
6.0
16.0
4.0
16.0
3.5
12.0
3.0
12.0
0.8
4.0
0.8
4.0
6.0
22.0
4.0
18.0
IH=Hold current-maximum current at which the device will not trip at 23°C still air.
IT=Trip current-maximum current at which the device will always trip at 23°C still air.
V MAX=Maximum voltage device can withstand without damage at its rated current.
VI-MAX=Maximum interrupt voltage device can withstand for short period of time. (Not for long term.)
I MAX=Maximum fault current device can withstand without damage at rated voltage (V MAX).
Pd=Typical power dissipated from device when in the tripped state in 23°C still air environment.
R MIN=Minimum device resistance at 23°C.
R1MAX=Maximum device resistance at 23°C, 1 hour after tripping.
Physical specifications:
Lead material: FRH080-250~FRH180-250 Tin plated copper, 22 AWG.
FRH150-600~FRH160-600 Tin plated copper, 22 AWG.
Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating: Flame retardant epoxy, meet UL-94V-0 requirement.
Figure 1
FRH PRODUCT DIMENSIONS (MILLIMETERS)
NOTE: All FRH products are designed to assist equipment to pass ITU,
UL1950 or GR1089 specification.
Part
A
B
C
D
E
Number Maximum Maximum Typical Minimum Maximum
FRH080-250UF 4.8
9.1
5
4.7
3.8
FRH080-250F
5.3
9.6
5
4.7
4.6
FRH110-250UF 5.3
9.4
5
4.7
3.8
FRH110-250F
5.8
9.9
5
4.7
4.6
FRH120-250UF 6.0
10.0
5
4.7
3.8
FRH120-250F
6.5
11.0
5
4.7
4.6
FRH145-250UF 6.0
10.0
5
4.7
3.8
FRH145-250F
6.5
11.0
5
4.7
4.6
FRH180-250UF 10.4
12.6
5
4.7
3.8
FRH180-250F
10.9
13.6
5
4.7
4.6
FRH150-600F
13.5
12.6
5
4.7
6
FRH160-600F
16.0
12.6
5
4.7
6
Lead Size: 22AWG (0.65mm)
Figure 2
Lead Size: 22AWG (0.65mm)
CAUTION: FRH devices are not intended for continous use of Line Voltage such as 120 VAC`600VAC and above.
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail Sales@rfeinc.com
C5EB08
REV 2007.03.1