English
Language : 

RD74VT1G245 Datasheet, PDF (7/14 Pages) Renesas Technology Corp – Bus Transceiver with 3-state Output / Dual Supply Voltage Translator
RD74VT1G245
Switching Characteristics (Cont.)
VCCA = 1.8±0.15 V
Ta = –40 to 85°C
From
VCCB= VCCB=
VCCB=
VCCB=
VCCB=
To 1.2 V 1.5±0.1 V 1.8±0.15 V 2.5±0.2 V 3.3±0.3 V
Test
Item Symbol (input) (output) Typ Min Max Min Max Min Max Min Max Unit conditions
Propagation tPLH
A
delay time
tPHL
B
9.8 2.0 9.6 1.5 6.5 1.0 4.6 1.0 3.8 ns CL = 15pF
9.8 2.0 9.6 1.5 6.5 1.0 4.6 1.0 3.8
RL = 2.0kΩ
tPLH
B
A
6.4 1.5 7.2 1.5 6.5 1.5 6.0 1.5 5.8
tPHL
6.4 1.5 7.2 1.5 6.5 1.5 6.0 1.5 5.8
Output
tHZ
DIR
Disable time tLZ
A
5.5 1.5 7.5 1.5 7.5 1.5 7.5 1.5 7.5 ns CL = 15pF
5.5 1.5 7.5 1.5 7.5 1.5 7.5 1.5 7.5
RL = 2.0kΩ
tHZ
DIR
B
12.0 2.0 11.5 1.5 9.2 1.0 7.2 1.0 7.0
Output
Enable time
tLZ
tZH*1
tZL*1
tZH*1
tZL*1
DIR
DIR
12.0 2.0 11.5 1.5 9.2 1.0 7.2 1.0 7.0
A
18.4  18.7  15.7  13.2  12.8 ns CL = 15pF
18.4  18.7  15.7  13.2  12.8
RL = 2.0kΩ
B
15.3  17.1  14.0  12.1  11.3
15.3  17.1  14.0  12.1  11.3
Note: 1. The enable time is a calculated value, derived using the formula shown in the section entitled enable times on
page 12.
VCCA = 1.5±0.1 V
Ta = –40 to 85°C
From
VCCB= VCCB=
VCCB=
VCCB=
VCCB=
To 1.2 V 1.5±0.1 V 1.8±0.15 V 2.5±0.2 V 3.3±0.3 V
Test
Item Symbol (input) (output) Typ Min Max Min Max Min Max Min Max Unit conditions
Propagation tPLH
A
delay time
tPHL
B
10.0 2.0 10.5 1.5 7.2 1.0 4.8 1.0 4.2 ns CL = 15pF
10.0 2.0 10.5 1.5 7.2 1.0 4.8 1.0 4.2
RL = 2.0kΩ
tPLH
B
A
8.0 2.0 10.5 2.0 9.6 2.0 9.2 2.0 8.8
tPHL
8.0 2.0 10.5 2.0 9.6 2.0 9.2 2.0 8.8
Output
tHZ
DIR
Disable time tLZ
A
6.0 2.0 10.0 2.0 10.0 2.0 10.0 2.0 10.0 ns CL = 15pF
6.0 2.0 10.0 2.0 10.0 2.0 10.0 2.0 10.0
RL = 2.0kΩ
tHZ
DIR
B
12.5 2.0 12.7 1.5 12.0 1.0 10.7 1.0 7.5
Output
Enable time
tLZ
tZH*1
tZL*1
tZH*1
tZL*1
DIR
DIR
12.5 2.0 12.7 1.5 12.0 1.0 10.7 1.0 7.5
A
20.5  23.2  21.6  19.9  16.3 ns CL = 15pF
20.5  23.2  21.6  19.9  16.3
RL = 2.0kΩ
B
16.0  20.5  17.2  14.8  14.2
16.0  20.5  17.2  14.8  14.2
Note: 1. The enable time is a calculated value, derived using the formula shown in the section entitled enable times on
page 12.
Rev.2.00 Apr. 01, 2005 page 7 of 13