DC Electrical Characteristics
Ta = –40 to 85°C
Item
Symbol VCC (V)*
Min
Typ Max
Unit Test Conditions
Input voltage
VIH
VIL
Output voltage
VOH
VOL
Input current
IIN
Quiescent supply ICC
current
2.0
1.5
——
V
2.3 to 2.7 VCC × 0.7 — —
3.0 to 3.6 VCC × 0.7 — —
4.5 to 5.5 VCC × 0.7 — —
2.0
—
— 0.5
2.3 to 2.7 —
— VCC × 0.3
3.0 to 3.6 —
— VCC × 0.3
4.5 to 5.5 —
— VCC × 0.3
Min to Max VCC – 0.1 — —
V
IOH = –50 µA
2.3
2.0
——
IOH = –2 mA
3.0
2.48
——
IOH = –6 mA
4.5
3.8
——
IOH = –12 mA
Min to Max —
— 0.1
V
IOL = 50 µA
2.3
—
— 0.4
IOL = 2 mA
3.0
—
— 0.44
IOL = 6 mA
4.5
—
— 0.55
IOL = 12 mA
0 to 5.5
—
— ±1
µA VIN = 5.5 V or GND
5.5
—
— 20
µA VIN = VCC or GND, IO = 0
Output leakage
IOFF
0
current
—
—5
µA VI or VO = 0 V to 5.5 V
Input capacitance CIN
3.3
—
1.7 —
pF VI = VCC or GND
Note: For conditions shown as Min or Max, use the appropriate values under recommended operating conditions.
Switching Characteristics
Item
Maximum clock
frequency
Propagation
delay time
Setup time
Pulse width
Ta = 25°C
Ta = –40 to 85°C
Symbol Min Typ Max Min
Max
fmax 50 90 — 40
—
30 60 — 25
—
tPLH/tPHL —
—
11.8 17.7 1.0
15.1 21.3 1.0
20.5
24.5
— 13.4 20.3 1.0
23.5
— 16.7 23.9 1.0
27.5
— 14.9 22.5 1.0
26.0
— 18.2 26.1 1.0
30.0
— 16.2 24.2 1.0
28.0
— 19.5 27.8 1.0
32.0
tPHL
— 10.8 14.8 1.0
17.0
— 14.2 17.4 1.0
20.0
tsu
6.0 — — 6.0
—
tw
5.0 — — 5.0
—
5.0 — — 5.0
—
Unit
MHz
ns
ns
ns
Test
Conditions
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
VCC = 2.5 ± 0.2 V
FROM TO
(Input) (Output)
CLK
QA
QB
QC
QD
CLR
Qn
CLR L before CLK ↓
CLR H
CLK H or L
Rev.3.00 Jun. 28, 2004 page 5 of 10