HD74LV2G66A Datasheet, PDF (6/12 Pages) Renesas Technology Corp – 2-channel Analog Switch | |||
|
◁ |
HD74LV2G66A
Switching Characteristics
⢠VCC = 1.8 ± 0.15 V
Item
Symbol
Propagation tPLH
delay time tPHL
Enable time tZH
tZL
Disable time tHZ
tLZ
Ta = 25°C
Min Typ
â 4.0
â 11.0
â 11.0
â 18.0
â 11.0
â 18.0
Max
13.0
23.0
24.0
44.0
21.0
46.0
Ta = â40 to 85°C Unit Test
FROM TO
Min Max
Conditions (Input) (Output)
â
19.0 ns CL = 15 pF IN/OUT OUT/IN
â
29.0
CL = 50 pF or OUT/IN or IN/OUT
â
29.0 ns CL = 15 pF C
â
51.0
CL = 50 pF
IN/OUT
or OUT/IN
â
29.0 ns CL = 15 pF C
â
53.0
CL = 50 pF
IN/OUT
or OUT/IN
⢠VCC = 2.5 ± 0.2 V
Item
Symbol
Propagation tPLH
delay time tPHL
Enable time tZH
tZL
Disable time tHZ
tLZ
Ta = 25°C
Min Typ
â 2.0
â 5.0
â 6.0
â 8.0
â 7.0
â 11.0
Max
10.0
12.0
15.0
25.0
15.0
25.0
Ta = â40 to 85°C Unit Test
FROM TO
Min Max
Conditions (Input) (Output)
â
16.0 ns CL = 15 pF IN/OUT OUT/IN
â
18.0
CL = 50 pF or OUT/IN or IN/OUT
â
20.0 ns CL = 15 pF C
â
32.0
CL = 50 pF
IN/OUT
or OUT/IN
â
23.0 ns CL = 15 pF C
â
32.0
CL = 50 pF
IN/OUT
or OUT/IN
⢠VCC = 3.3 ± 0.3 V
Item
Symbol
Propagation tPLH
delay time tPHL
Enable time tZH
tZL
Disable time tHZ
tLZ
Ta = 25°C
Min Typ
â 1.5
â 4.0
â 4.0
â 6.0
â 5.0
â 8.0
Max
6.0
9.0
11.0
18.0
11.0
18.0
Ta = â40 to 85°C Unit Test
FROM TO
Min Max
Conditions (Input) (Output)
â
10.0 ns CL = 15 pF IN/OUT OUT/IN
â
12.0
CL = 50 pF or OUT/IN or IN/OUT
â
15.0 ns CL = 15 pF C
â
22.0
CL = 50 pF
IN/OUT
or OUT/IN
â
15.0 ns CL = 15 pF C
â
22.0
CL = 50 pF
IN/OUT
or OUT/IN
Rev.4.00, Sep.30.2003, page 6 of 11
|
▷ |