HD74LV1GT14A_15 Datasheet, PDF (6/9 Pages) Renesas Technology Corp – Inverter with Schmitt-trigger Input / | |||
|
◁ |
HD74LV1GT14A
Electrical Characteristic
⢠Ta = â40 to 85°C
Item
Symbol VCC (V) *
Min
Typ
Max
Unit
Test condition
3.0
â
â
1.5
VT+
3.6
4.5
â
â
1.6
â
â
1.9
5.5
â
â
2.1
3.0
0.3
â
â
Input voltage
VTâ
3.6
4.5
0.4
â
â
V
0.5
â
â
5.5
0.6
â
â
3.0
0.3
â
1.2
3.6
âVT
4.5
0.3
â
1.3
0.4
â
1.4
5.5
0.4
â
1.5
Min to Max VCCâ0.1
â
â
IOH = â50 µA
VOH
3.0
2.48
â
â
IOH = â6 mA
Output voltage
4.5
3.8
â
â
V
IOH = â12 mA
Min to Max â
â
0.1
IOL = 50 µA
VOL
3.0
â
â
0.44
IOL = 6 mA
4.5
â
â
0.55
IOL = 12 mA
Input current
IIN
0 to 5.5
â
â
±1
µA VIN = 5.5 V or GND
Quiescent
supply current
ICC
5.5
âICC
5.5
â
â
10
µA
VIN = VCC or GND,
IO = 0
â
â
1.5
mA One input VIN = 3.4 V,
other input VCC or GND
Output leakage current IOFF
0
â
â
5
µA VIN or VO = 0 to 5.5 V
Input capacitance
CIN
5.0
â
3.0
â
pF VIN = VCC or GND
Note: For conditions shown as Min or Max, use the appropriate values under recommended operating conditions.
Switching Characteristics
⢠VCC = 3.3 ± 0.3 V
Item
Symbol
Propagation
tPLH
delay time
tPHL
Ta = 25°C
Min Typ Max
â
7.5 12.5
â 10.0 15.0
⢠VCC = 5.0 ± 0.5 V
Item
Symbol
Propagation
tPLH
delay time
tPHL
Ta = 25°C
Min Typ Max
â
5.0
7.6
â
6.5
9.6
Ta = â40 to 85°C
Min
Max
1.0
14.5
1.0
17.0
Ta = â40 to 85°C
Min
Max
1.0
9.0
1.0
11.0
Unit
Test
FROM TO
Conditions (Input) (Output)
ns CL = 15 pF
A or B
Y
CL = 50 pF
Unit
Test
FROM TO
Conditions (Input) (Output)
ns CL = 15 pF
A
Y
CL = 50 pF
Operating Characteristics
⢠CL = 50 pF
Item
Symbol VCC (V)
Power dissipation
capacitance
CPD
5.0
Ta = 25°C
Min
Typ
Max
â
10.0
â
Unit
Test Conditions
pF f = 10 MHz
REJ03D0119-0700 Rev.7.00, Mar 21, 2008
Page 4 of 6
|
▷ |