English
Language : 

HD74LV1GT02A_15 Datasheet, PDF (6/9 Pages) Renesas Technology Corp – 2–input NOR Gate / CMOS Logic Level Shifter
HD74LV1GT02A
Electrical Characteristic
• Ta = –40 to 85°C
Item
Symbol VCC (V) *
Min
Typ
Max
Unit
Test condition
Input voltage
3.0 to 3.6
1.5
—
—
VIH
4.5 to 5.5
2.0
—
—
V
3.0 to 3.6
—
—
0.6
VIL
4.5 to 5.5
—
—
0.8
Hysteresis voltage
3.3
VH
5.0
—
0.10
—
—
0.15
—
V
VT+ – VT–
Min to Max VCC–0.1
—
—
IOH = –50 µA
VOH
3.0
2.48
—
—
IOH = –6 mA
Output voltage
4.5
3.8
—
—
V
IOH = –12 mA
Min to Max —
—
0.1
IOL = 50 µA
VOL
3.0
—
—
0.44
IOL = 6 mA
4.5
—
—
0.55
IOL = 12 mA
Input current
IIN
0 to 5.5
—
—
±1
µA VIN = 5.5 V or GND
Quiescent
supply current
ICC
5.5
—
—
10
µA
VIN = VCC or GND,
IO = 0
∆ICC
5.5
—
—
1.5
mA One input VIN = 3.4 V,
other input VCC or GND
Output leakage current IOFF
0
—
—
5
µA VIN or VO = 0 to 5.5 V
Input capacitance
CIN
5.0
—
2.5
—
pF VIN = VCC or GND
Note: For conditions shown as Min or Max, use the appropriate values under recommended operating conditions.
Switching Characteristics
• VCC = 3.3 ± 0.3 V
Item
Symbol
Propagation
tPLH
delay time
tPHL
Ta = 25°C
Min Typ Max
—
7.0 11.0
—
9.0 14.0
• VCC = 5.0 ± 0.5 V
Item
Symbol
Propagation
tPLH
delay time
tPHL
Ta = 25°C
Min Typ Max
—
5.0
6.2
—
6.5
9.0
Ta = –40 to 85°C
Min
Max
1.0
13.0
1.0
15.5
Ta = –40 to 85°C
Min
Max
1.0
7.5
1.0
10.0
Unit
Test
FROM TO
Conditions (Input) (Output)
ns CL = 15 pF
A or B
Y
CL = 50 pF
Unit
Test
FROM TO
Conditions (Input) (Output)
ns CL = 15 pF
A or B
Y
CL = 50 pF
Operating Characteristics
• CL = 50 pF
Item
Symbol VCC (V)
Power dissipation
capacitance
CPD
5.0
Ta = 25°C
Min
Typ
Max
—
10.3
—
Unit
Test Conditions
pF f = 10 MHz
REJ03D0116-0900 Rev.9.00, Mar 21, 2008
Page 4 of 6