English
Language : 

R5F21364MNFP Datasheet, PDF (55/61 Pages) Renesas Technology Corp – The R8C/36M Group has data flash (1 KB × 4 blocks) with the background operation
Under development Preliminary document
Specifications in this document are tentative and subject to change.
R8C/36M Group
5. Electrical Characteristics
Timing requirements (Unless Otherwise Specified: VCC = 2.2 V, VSS = 0 V, Topr = 25 °C)
Table 5.34 External Clock Input (XOUT, XCIN)
Symbol
tc(XOUT)
tWH(XOUT)
tWL(XOUT)
tc(XCIN)
tWH(XCIN)
tWL(XCIN)
XOUT input cycle time
XOUT input “H” width
XOUT input “L” width
XCIN input cycle time
XCIN input “H” width
XCIN input “L” width
Parameter
Standard
Unit
Min.
Max.
200
—
ns
90
—
ns
90
—
ns
14
TBD
µs
7
TBD
µs
7
TBD
µs
External clock input
tWH(XOUT),
tWH(XCIN)
tC(XOUT), tC(XCIN)
tWL(XOUT), tWL(XCIN)
Figure 5.18 External Clock Input Timing Diagram when VCC = 2.2 V
VCC = 2.2 V
Table 5.35 TRAIO Input
Symbol
tc(TRAIO)
tWH(TRAIO)
tWL(TRAIO)
TRAIO input cycle time
TRAIO input “H” width
TRAIO input “L” width
Parameter
TRAIO input
tWH(TRAIO)
tC(TRAIO)
tWL(TRAIO)
Figure 5.19 TRAIO Input Timing Diagram when VCC = 2.2 V
Standard
Unit
Min.
Max.
500
—
ns
200
—
ns
200
—
ns
VCC = 2.2 V
Table 5.36 TRFI Input
Symbol
tc(TRFI)
tWH(TRFI)
tWL(TRFI)
TRFI input cycle time
TRFI input “H” width
TRFI input “L” width
Parameter
Standard
Unit
Min.
Max.
2000 (1)
—
ns
1000 (2)
—
ns
1000 (2)
—
ns
Notes:
1. When using timer RF input capture mode, adjust the cycle time to (1/timer RF count source frequency × 3) or above.
2. When using timer RF input capture mode, adjust the pulse width to (1/timer RF count source frequency × 1.5) or above.
TRFI input
Figure 5.20
tWH(TRFI)
tc(TRFI)
tWL(TRFI)
TRFI Input Timing Diagram when VCC = 2.2 V
R01DS0086EJ0010 Rev.0.10
Mar 09, 2011
VCC = 2.2 V
Page 55 of 58