English
Language : 

HD74LV1G126A_08 Datasheet, PDF (5/8 Pages) Renesas Technology Corp – Bus Buffer Gate with 3-state Output
HD74LV1G126A
Switching Characteristics
• VCC = 1.8 ± 0.15 V
Item
Symbol
Propagation
tPLH
delay time
tPHL
Enable time
tZH
tZL
Disable time
tHZ
tLZ
Ta = 25°C
Min Typ Max
— 13.5 23.5
— 19.0 33.0
— 13.7 26.5
— 20.5 36.0
—
8.3 20.0
— 13.0 29.5
• VCC = 2.5 ± 0.2 V
Item
Symbol
Propagation
tPLH
delay time
tPHL
Enable time
tZH
tZL
Disable time
tHZ
tLZ
Ta = 25°C
Min Typ Max
—
7.1 13.0
—
9.2 16.5
—
7.4 13.0
—
9.5 16.5
—
5.7 14.7
—
8.1 18.2
• VCC = 3.3 ± 0.3 V
Item
Symbol
Propagation
tPLH
delay time
tPHL
Enable time
tZH
tZL
Disable time
tHZ
tLZ
Ta = 25°C
Min Typ Max
—
5.0
8.0
—
6.4 11.5
—
5.1
8.0
—
6.6 11.5
—
4.4
9.7
—
6.1 13.2
• VCC = 5.0 ± 0.5 V
Item
Symbol
Propagation
tPLH
delay time
tPHL
Enable time
tZH
tZL
Disable time
tHZ
tLZ
Ta = 25°C
Min Typ Max
—
3.5
5.5
—
4.6
7.5
—
3.6
5.1
—
4.6
7.1
—
3.3
6.8
—
4.3
8.8
Ta = –40 to 85°C
Min
Max
1.0
26.0
1.0
36.0
1.0
29.0
1.0
38.0
1.0
22.5
1.0
32.0
Ta = –40 to 85°C
Min
Max
1.0
15.5
1.0
18.5
1.0
15.5
1.0
18.5
1.0
17.0
1.0
20.5
Ta = –40 to 85°C
Min
Max
1.0
9.5
1.0
13.0
1.0
9.5
1.0
13.0
1.0
11.5
1.0
15.0
Ta = –40 to 85°C
Min
Max
1.0
6.5
1.0
8.5
1.0
6.0
1.0
8.0
1.0
8.0
1.0
10.0
Operating Characteristics
• CL = 50 pF
Item
Symbol VCC (V)
Power dissipation
capacitance
3.3
CPD
5.0
Ta = 25°C
Min
Typ
Max
—
10.5
—
—
11.5
—
Unit
ns
ns
ns
Test
Conditions
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
FROM TO
(Input) (Output)
A
Y
OE
Y
OE
Y
Unit
ns
ns
ns
Test
Conditions
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
FROM TO
(Input) (Output)
A
Y
OE
Y
OE
Y
Unit
ns
ns
ns
Test
Conditions
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
FROM TO
(Input) (Output)
A
Y
OE
Y
OE
Y
Unit
ns
ns
ns
Test
Conditions
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
FROM TO
(Input) (Output)
A
Y
OE
Y
OE
Y
Unit
Test Conditions
pF f = 10 MHz
REJ03D0072-0700 Rev.7.00, Mar 21, 2008