HD74LV157A
Recommended Operating Conditions
Item
Symbol Min
Max
Supply voltage range
Input voltage range
Output voltage range
Output current
VCC
2.0
5.5
VI
0
5.5
VO
0
VCC
IOH
—
–50
—
–2
—
–6
—
–12
IOL
—
50
—
2
—
6
—
12
Input transition rise or fall rate
∆t/∆v
0
200
0
100
0
20
Operating free-air temperature
Ta
–40
85
Note: Unused or floating inputs must be held high or low.
Logic Diagram
1A
1B
2A
2B
3A
3B
4A
4B
Select
Unit
V
V
V
µA
mA
µA
mA
ns/V
°C
Conditions
H or L
VCC = 2.0 V
VCC = 2.3 to 2.7 V
VCC = 3.0 to 3.6 V
VCC = 4.5 to 5.5 V
VCC = 2.0 V
VCC = 2.3 to 2.7 V
VCC = 3.0 to 3.6 V
VCC = 4.5 to 5.5 V
VCC = 2.3 to 2.7 V
VCC = 3.0 to 3.6 V
VCC = 4.5 to 5.5 V
1Y
2Y
3Y
4Y
Strobe