English
Language : 

HD74LV139A_15 Datasheet, PDF (5/9 Pages) Renesas Technology Corp – Dual 2-to-4-line Decoders / Demultiplexers
HD74LV139A
Recommended Operating Conditions
Item
Symbol
Min
Supply voltage range
Input voltage range
VCC
2.0
VI
0
Output voltage range
VO
0
Output current
IOH
—
—
—
—
IOL
—
—
—
—
Input transition rise or fall rate
∆t /∆v
0
0
0
Operating free-air temperature
Ta
–40
Note: Unused or floating inputs must be held high or low.
Max
5.5
5.5
VCC
–50
–2
–6
–12
50
2
6
12
200
100
20
85
Unit
V
V
V
µA
mA
µA
mA
ns/V
°C
Conditions
VCC = 2.0 V
VCC = 2.3 to 2.7 V
VCC = 3.0 to 3.6 V
VCC = 4.5 to 5.5 V
VCC = 2.0 V
VCC = 2.3 to 2.7 V
VCC = 3.0 to 3.6 V
VCC = 4.5 to 5.5 V
VCC = 2.3 to 2.7 V
VCC = 3.0 to 3.6 V
VCC = 4.5 to 5.5 V
DC Electrical Characteristics
Ta = –40 to 85°C
Item
Input voltage
Output voltage
Input current
Quiescent supply
current
Symbol
VIH
VIL
VOH
VOL
IIN
ICC
VCC (V)*
2.0
2.3 to 2.7
3.0 to 3.6
4.5 to 5.5
2.0
2.3 to 2.7
3.0 to 3.6
4.5 to 5.5
Min to Max
2.3
3.0
4.5
Min to Max
2.3
3.0
4.5
0 to 5.5
5.5
Min
1.5
VCC× 0.7
VCC× 0.7
VCC× 0.7
—
—
—
—
VCC – 0.1
2.0
2.48
3.8
—
—
—
—
—
—
Typ
Max
——
——
——
——
— 0.5
— VCC× 0.3
— VCC× 0.3
— VCC× 0.3
——
——
——
——
— 0.1
— 0.4
— 0.44
— 0.55
— ±1
— 20
Unit
Test Conditions
V
V
IOH = –50 µA
IOH = –2 mA
IOH = –6 mA
IOH = –12 mA
IOL = 50 µA
IOL = 2 mA
IOL = 6 mA
IOL = 12 mA
µA VIN = 5.5 V or GND
µA VIN = VCC or GND, IO = 0
Output leakage
IOFF
0
current
—
—5
µA VI or VO = 0 V to 5.5 V
Input capacitance CIN
3.3
—
3.3 —
pF VI = VCC or GND
Note: For conditions shown as Min or Max, use the appropriate values under recommended operating conditions.
Rev.1.00 Aug. 24, 2004 page 3 of 6