5. Connection
To connect the debugging MCU board and user system,
follow the procedure below.
The R0E55630EDMB01 (this product) can be used for
debugging and on-board evaluation in common by
mounting the NQPACK100SD-ND on the user system.
(1) For debugging
Flexible cable of
the E20 emulator
4
R0E55630EDMB01
(1) For debugging
1. Mount the NQPACK100SD-ND on the user system.
Be sure to check that the location of pin 1 is correct.
2. Install the YQPACK100SD after checking for a match
with the position of pin 1 for the NQPACK100SD-ND.
Then use the YQ-GUIDE-S1 to affix the
YQPACK100SD to the NQPACK100SD-ND.
● Do NOT use the screws included with the
YQPACK100SD for fixing the YQPACK100SD.
● Do NOT use the screwdriver included with the
NQPACK100SD-ND for fixing the
YQ-GUIDE-S1. That is used only for the
HQPACK100SD. Note that you need to provide
your own screwdriver.
3. Connect the R0E55630EDMB01 after checking for a
match with the position of pin 1 for the YQPACK100SD.
4. Install the connector of the flexible cable from the E20
emulator to the 38-pin connector on the
R0E55630EDMB01.
Hold the R0E55630EDMB01 while connecting the
cable to avoid imposing heavy pressure on the 38-pin
connector of the R0E55630EDMB01.
38-pin
connector
R0E55630EVKZ00
R0E55630EPFK20
(back side:
YQSOCKET100SDF)
Use a flat-bladed
3
screwdriver.
YQ-GUIDE-S1(×4)
YQPACK100SD
(2) For on-board
evaluation
HQPACK100SD
(not included)
2
NQPACK100SD-ND
MCU
5
1
100-pin, 0.5mm pitch
(PLQP0100KB-A) pad pattern
indicates pin 1 in this example.
Check that the pin-1 positions on the foot pattern and
all of the components are correctly aligned.
(2) For on-board evaluation
5. Mount an MCU with on-chip flash memory and the
HQPACK100SD (not included) in order on the
NQPACK100SD-ND on the user system.
Figure 3 Connections of the User System and This
Product
Before using the R0E55630EDMB01, be sure to read section 7, Notes on Usage.
WARNING
Warnings to Be Taken for Connection:
• Always switch OFF the emulator, this product, and the user system before connecting or disconnecting
the emulator. Failure to do so will create a FIRE HAZARD and will damage the emulator, this product,
and the user system.
• Make sure that the connectors on both ends of the user-system interface cable are facing the right way
relative to the user-side connector on the emulator and the 38-pin connector on this product,
respectively. Incorrect connection will create a FIRE HAZARD and will damage the emulator, this
product, and the user system.
CAUTION
Cautions to Be Taken for Mounting the NQPACK:
• Check the locations of pin 1 before mounting the NQPACK.
• The tightening torque must be no greater than 0.054 N•m. If the applied torque is not accurately
measurable, stop tightening when the force required to turn the screw (YQ-GUIDE-S1) becomes
significantly greater than that required at the start of tightening. Tightening a screw too much may break
the screw hole of the NQPACK or lead to a faulty connection by cracking solder on the NQPACK side.
• Failure of conduction during operation may be due to a crack in the solder for the NQPACK. Check
conduction with a tester and re-solder the NQPACK as required.