English
Language : 

BCR8FM-12LB_15 Datasheet, PDF (4/8 Pages) Renesas Technology Corp – 600V - 8A - Triac Medium Power Use
BCR8FM-12LB
Maximum Transient Thermal Impedance
Characteristics (Junction to ambient)
103
7
5
No Fins
3
2
102
7
5
3
2
101
7
5
3
2
100
7
5
3
2
10–1101 2 3 5 7102 2 3 5 7103 2 3 5 7104 2 3 5 7105
Conduction Time (Cycles at 60Hz)
Allowable Case Temperature vs.
RMS On-State Current
160
Curves apply regardless
140
of conduction angle
120
100
80
60
40
360° Conduction
20
Resistive,
inductive loads
0
0 2 4 6 8 10 12 14 16
RMS On-State Current (A)
Allowable Ambient Temperature vs.
RMS On-State Current
160
Natural convection
140
No Fins
Curves apply regardless
120
of conduction angle
Resistive, inductive loads
100
80
60
40
20
0
0 0.5 1.0 1.5 2.0 2.5 3.0
RMS On-State Current (A)
Preliminary
Maximum On-State Power Dissipation
16
14
12 360° Conduction
Resistive,
10 inductive loads
8
6
4
2
0 2 4 6 8 10 12 14 16
RMS On-State Current (A)
Allowable Ambient Temperature vs.
RMS On-State Current
160
All fins are black painted
140
aluminum and greased
120 × 120 × t2.3
120
100 × 100 × t2.3
100
60 × 60 × t2.3
80
60
Curves apply
regardless of
40
conduction angle
Resistive,
20
inductive loads
Natural convection
0
0 2 4 6 8 10 12 14 16
RMS On-State Current (A)
Repetitive Peak Off-State Current vs.
Junction Temperature
106
7
5
3
2
105
7
5
3
2
104
7
5
3
2
103
7
5
3
2
102
–60 –40–20 0
Typical Example
20 40 60 80 100 120 140 160
Junction Temperature (°C)
R07DS1186EJ0100 Rev.1.00
Mar 03, 2014
Page 4 of 7