English
Language : 

BCR5PM-14LG Datasheet, PDF (4/8 Pages) Renesas Technology Corp – Triac Medium Power Use
BCR5PM-14LG
Maximum Transient Thermal Impedance
Characteristics (Junction to ambient)
103
7
5
No Fins
3
2
102
7
5
3
2
101
7
5
3
2
100
7
5
3
2
10–1101 2 3 5 7102 2 3 5 7103 2 3 5 7104 2 3 5 7105
Conduction Time (Cycles at 60Hz)
Allowable Case Temperature vs.
RMS On-State Current
160
Curves apply regardless
140
of conduction angle
120
100
80
60
40
360° Conduction
20 Resistive,
inductive loads
0
012345678
RMS On-State Current (A)
Allowable Ambient Temperature vs.
RMS On-State Current
160
Natural convection
140
No Fins
Curves apply regardless
120
of conduction angle
Resistive, inductive loads
100
80
60
40
20
0
0 0.5 1.0 1.5 2.0 2.5 3.0
RMS On-State Current (A)
Maximum On-State Power Dissipation
10
9
8
7
6
5
4
3
2
360° Conduction
1
Resistive,
inductive loads
0
0 1 2 3 4 5 6 7 8 9 10
RMS On-State Current (A)
Allowable Ambient Temperature vs.
RMS On-State Current
160
140
60 × 60 × t2.3
120
100 × 100 × t2.3
100
120 × 120 × t2.3
80
60
40 Curves apply regardless
of conduction angle
20 Resistive, inductive loads
Natural convection
0
01234
All fins are
black painted
aluminum
and greased
5678
RMS On-State Current (A)
Repetitive Peak Off-State Current vs.
Junction Temperature
106
7
5
3
2
105
7
5
3
2
104
7
5
3
2
103
7
5
3
2
102
–60 –40–20 0
Typical Example
20 40 60 80 100 120 140 160
Junction Temperature (°C)
REJ03G1558-0100 Rev.1.00 Jul 06, 2007