English
Language : 

BCR30AM-12LA Datasheet, PDF (4/7 Pages) Renesas Technology Corp – Triac Medium Power Use
BCR30AM-12LA
Maximum On-State Power Dissipation
50
40
360° Conduction
Resistive,
30 inductive loads
20
10
0
0
10 20 30 40 50
RMS On-State Current (A)
Allowable Ambient Temperature vs.
RMS On-State Current
160
All fins are black painted
140
aluminum and greased
Curves apply regardless
120
of conduction angle
Resistive, inductive loads
100
Natural convection
80
160 × 160 × t2.3
60
120 × 120 × t2.3
40
100 × 100 × t2.3
20
0
0 5 10 15 20 25 30 35 40
RMS On-State Current (A)
Repetitive Peak Off-State Current vs.
Junction Temperature
105
7
Typical Example
5
3
2
104
7
5
3
2
103
7
5
3
2
102
–60 –40 –20 0 20 40 60 80 100 120 140
Junction Temperature (°C)
Allowable Case Temperature vs.
RMS On-State Current
160
Curves apply regardless
140
of conduction angle
120
100
80
60
40
20 Resistive,
inductive loads
0
0
10
20
30
40
RMS On-State Current (A)
Allowable Ambient Temperature vs.
RMS On-State Current
160
Natural convection
140
No fins
Curves apply regardless
120
of conduction angle
Resistive, inductive loads
100
80
60
40
20
0
0
1
2
3
4
5
RMS On-State Current (A)
Holding Current vs.
Junction Temperature
103
7
Typical Example
5
4
3
2
102
7
5
4
3
2
101
–60 –40 –20 08 20 40 60 0 100 120 140
Junction Temperature (°C)
REJ03G0342-0300 Rev.3.00 Nov 30, 2007