English
Language : 

HD74LS11 Datasheet, PDF (3/6 Pages) Hitachi Semiconductor – Triple 3-input Positive AND Gates(with Open Collector Outputs)
HD74LS11 / HD74LS15
Recommended Operating Conditions
• HD74LS11
Item
Supply voltage
Output current
Operating temperature
Symbol
VCC
IOH
IOL
Topr
Min
4.75
—
—
–20
Typ
5.00
—
—
25
Max
5.25
–400
8
75
Unit
V
µA
mA
°C
• HD74LS15
Item
Supply voltage
Output voltage
Output current
Operating temperature
Symbol
VCC
VOH
IOL
Topr
Min
4.75
—
—
–20
Typ
5.00
—
—
25
Max
5.25
5.5
8
75
Unit
V
V
mA
°C
Electrical Characteristics
• HD74LS11
Item
Input voltage
Output voltage
Symbol
VIH
VIL
VOH
VOL
IIH
Input current
IIL
II
Short-circuit output
current
IOS
Supply current
ICCH
ICCL
Input clamp voltage
VIK
Note: * VCC = 5 V, Ta = 25°C
• HD74LS15
min.
2.0
—
2.7
—
—
—
—
—
–20
—
—
—
Item
Input voltage
Symbol
VIH
VIL
Output voltage
VOL
IIH
Input current
IIL
II
Output current
IOH
Supply current
ICCH
ICCL
Input clamp voltage
VIK
Note: * VCC = 5 V, Ta = 25°C
min.
2.0
—
—
—
—
—
—
—
—
—
—
typ.*
—
—
—
—
—
—
—
—
—
1.8
3.3
—
typ.*
—
—
—
—
—
—
—
—
1.8
3.3
—
max.
—
0.8
—
0.5
0.4
20
–0.4
0.1
–100
3.6
6.6
–1.5
max.
—
0.8
0.5
0.4
20
–0.4
0.1
100
3.6
6.6
–1.5
Unit
V
V
V
V
µA
mA
mA
mA
mA
mA
V
(Ta = –20 to +75 °C)
Condition
VCC = 4.75 V, VIL = 2 V, IOH = –400 µA
IOL = 8 mA
IOL = 4 mA
VCC = 4.75 V, VIH = 0.8 V
VCC = 5.25 V, VI = 2.7 V
VCC = 5.25 V, VI = 0.4 V
VCC = 5.25 V, VI = 7 V
VCC = 5.25 V
VCC = 5.25 V
VCC = 5.25 V
VCC = 4.75 V, IIN = –18 mA
Unit
V
V
V
µA
mA
mA
µA
mA
mA
V
(Ta = –20 to +75 °C)
Condition
IOL = 8 mA
IOL = 4 mA
VCC = 4.75 V, VIH = 0.8 V
VCC = 5.25 V, VI = 2.7 V
VCC = 5.25 V, VI = 0.4 V
VCC = 5.25 V, VI = 7 V
VCC = 4.75 V, VOH = 5.5 V
VCC = 5.25 V
VCC = 5.25 V
VCC = 4.75 V, IIN = –18 mA
Rev.3.00, Jul.13.2005, page 3 of 5