English
Language : 

HD151015_15 Datasheet, PDF (3/11 Pages) Renesas Technology Corp – 9 bit Level Shifter/Transceiver With 3 State Outputs
HD151015
Recommended Operating Conditions
Item
Supply voltage
Input voltage
Output voltage
Operating Temperature
Input Rise and Fall Time*1
Symbol
VCCA, B
VIN
VOUT
TA
tr, tf
Rating
2.0 to 6.0
0 to VCC
0 to VCC
–40 to +85
8
Unit
V
V
V
°C
ns/V
Note: 1. The item guarantees maximum limit when one input switches.
Waveform: Refer to test circuit of switching characteristics.
Conditions
VCCB ≥ VCCA – 0.5 V
VCC@3.0 V (Input DiR, G, A)
VCC@4.5 V (Input B)
VCC@5.5 V (Input B)
Logick Diagram
DIR
Transceiver(1/9)
A
B
Level
G
Change
VCCA System System
VCCB System
Electrical Characteristics
Ta = –40 to
Sym- VCCA VCCB
Ta = 25°C
85°C
Item
bol (V) (V) Min Typ Max Min Max
Input Voltage VIH 3.0 3.0 2.1 1.5 — 2.1 —
4.5 4.5 3.15 2.25 — 3.15 —
5.5 5.5 3.85 2.75 — 3.85 —
VIL 3.0 3.0 — 1.5 0.9 — 0.9
4.5 4.5 — 2.25 1.35 — 1.35
5.5 5.5 — 2.75 1.65 — 1.65
Output
VOH 2.7 4.5 2.6 2.69 — 2.6 —
Voltage
2.7 4.5 4.4 4.49 — 4.4 —
2.7 4.5 2.3 — — 2.2 —
2.7 4.5 3.9 — — 3.8 —
VOL 2.7 4.5 — 0.001 0.1 — 0.1
2.7 4.5 — — 0.32 — 0.37
Input Current IIN 3.3 5.5 — — ±0.1 — ±1.0
Off State
Output
IOZ 3.3 5.5 — — ±0.5 — ±5.0
Current
Supply
ICCA.B 3.3 5.5 — — 8.0 — 80
Current
ICCA 5.5 0 — — 8.0 — 80
Note: 1. A: Output A, B: Output B, A.B: Output A.B
Unit
V
V
V
V
V
V
µA
µA
µA
µA
Conditions
VOUT = 0.1 V or VCC – 0.1 V
VOUT = 0.1 V or VCC – 0.1 V
VIN = VIL or VIH, IOH = –50 µA A*1
VIN = VIL or VIH, IOH = –50 µA B
VIN =
IOH = –4 mA
A
VIL or VIH
IOH = –12 mA B
VIN = VIL or VIH, IOL = 50 µA
A.B
VIN = VIL or VIH, IOL = 12 mA A.B
VIN = VCC or GND
VIN(G) = VIH, VIN = VCC or GND,
VOUT = VCC or GND
VIN = VCC or GND
VIN = VCC or GND, B Input OPEN
R04DS0043EJ0600 Rev.6.00
May 30, 2014
Page 3 of 10