BCR8LM-12LA_15 Datasheet, PDF (2/7 Pages) Renesas Technology Corp – 600V - 8A - Triac Medium Power Use | |||
|
◁ |
BCR8LM-12LA
Preliminary
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Test conditions
Repetitive peak off-state current
IDRM
â
â
2.0
mA Tj = 125ï°C, VDRM applied
On-state voltage
VTM
â
â
1.6
V
Tc = 25ï°C, ITM = 12 A,
instantaneous measurement
Holding current
IH
â
10
â
mA Tj = 25ï°C, VD = 12 V, RGT1 =â ï
Gate trigger voltage Note2
ï
VFGTï
â
â
1.5
V
Tj = 25ï°C, VD = 6 V, RL = 6 ï,
ïï
VRGTï
â
â
1.5
V
RG = 330 ï
ïïï
VRGTïïï
â
â
1.5
V
Gate trigger current Note2
ï
IFGTï
â
â
10
mA Tj = 25ï°C, VD = 6 V, RL = 6 ï,
ïï
IRGTï
â
â
10
mA RG = 330 ï
ïïï
IRGTïïï
â
â
10
mA
Gate non-trigger voltage
Thermal resistance
VGD
0.2
â
â
V
Tj = 125ï°C, VD = 1/2 VDRM
Rth (j-c)
â
â
4.3
ï°C/W Junction to caseNote3
Notes: 1. Gate open.
2. Measurement using the gate trigger characteristics measurement circuit.
3. The contact thermal resistance Rth (c-f) in case of greasing is 0.5ï°C/W.
4. Make sure that your finished product containing this device meets your safe isolation requirements.
For safety, it is advisable that heatsink is electrically floating.
R07DS0683EJ0100 Rev.1.00
Feb 25, 2013
Page 2 of 6
|
▷ |