English
Language : 

BCR25FM-12LB_15 Datasheet, PDF (2/8 Pages) Renesas Technology Corp – 600V - 25A - Triac Medium Power Use
BCR25FM-12LB
Preliminary
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Test conditions
Repetitive peak off-state current
IDRM
—
—
3.0
mA Tj = 125°C, VDRM applied
—
—
5.0
mA Tj = 150°C, VDRM applied
On-state voltage
VTM
—
—
1.5
V
Tc = 25°C, ITM = 40 A,
instantaneous measurement
Gate trigger voltageNote2
Ι
VFGTΙ
—
—
2.0
V Tj = 25°C, VD = 6 V, RL = 6 Ω,
ΙΙ
VRGTΙ
—
—
2.0
V
RG = 330 Ω
ΙΙΙ
VRGTΙΙΙ
—
—
2.0
V
Gate trigger curentNote2
Ι
IFGTΙ
—
—
50
mA Tj = 25°C, VD = 6 V, RL = 6 Ω,
ΙΙ
IRGTΙ
—
—
50
mA RG = 330 Ω
ΙΙΙ
IRGTΙΙΙ
—
—
50
mA
Gate non-trigger voltage
VGD
0.2
—
—
V
Tj = 125°C, VD = 1/2 VDRM
Thermal resistance
0.1
—
—
V
Tj = 150°C, VD = 1/2 VDRM
Rth (j-c)
—
—
2.8
°C/W Junction to caseNote3
Critical-rate of rise of off-state
(dv/dt)c 10
—
—
V/μs Tj = 125°C
commutation voltageNote4
1
—
—
V/μs Tj = 150°C
Notes: 1. Gate open.
2. Measurement using the gate trigger characteristics measurement circuit.
3. The contact thermal resistance Rth (c-f) in case of greasing is 0.5°C/W.
4. Test conditions of the critical-rate of rise of off-state commutation voltage is shown in the table below.
5. Make sure that your finished product containing this device meets your safe isolation requirements.
For safety, it's advisable that heatsink is electrically floating.
Test conditions
1. Junction temperature
Tj = 125°C/150°C
2. Rate of decay of on-state commutating current
(di/dt)c = –13 A/ms
3. Peak off-state voltage
VD = 400 V
Commutating voltage and current waveforms
(inductive load)
Supply Voltage
Time
Main Current
Main Voltage
(dv/dt)c
(di/dt)c
Time
Time
VD
R07DS0964EJ0100 Rev.1.00
Feb 28, 2014
Page 2 of 7