English
Language : 

BCR20FM-12LB_15 Datasheet, PDF (2/8 Pages) Renesas Technology Corp – 600V - 20A - Triac Medium Power Use
BCR20FM-12LB
Preliminary
Electrical Characteristics
Parameter
Symbol
Rated value
Unit
Min. Typ. Max.
Test conditions
Repetitive peak off-state current
IDRM
—
On-state voltage
VTM
—
Gate trigger voltageNote2

VFGT
—

VRGT
—
Gate trigger curentNote2
 VRGT
—

IFGT
—

IRGT
—

IRGT
—
—
3.0
mA Tj = 150C, VDRM applied
—
1.5
V
Tc = 25C, ITM = 30A,
instantaneous measurement
—
1.5
—
1.5
V
Tj = 25C, VD = 6 V, RL = 6 ,
V
RG = 330 
—
1.5
V
—
30 Note5
mA Tj = 25C, VD = 6 V, RL = 6 ,
—
30 Note5
mA RG = 330 
—
30 Note5
mA
Gate non-trigger voltage
VGD
0.2
—
—
V
Tj = 125C, VD = 1/2 VDRM
Thermal resistance
0.1
—
—
Tj = 150C, VD = 1/2 VDRM
Rth (j-c)
—
—
2.3
C/W Junction to caseNote3
Critical-rate of rise of off-state
(dv/dt)c 10
—
—
V/s Tj = 125C
commutation voltageNote4
1
—
—
Tj = 150C
Notes: 1. Gate open.
2. Measurement using the gate trigger characteristics measurement circuit.
3. The contact thermal resistance Rth (c-f) in case of greasing is 0.5C/W.
4. Test conditions of the critical-rate of rise of off-state commutation voltage is shown in the table below.
5. High sensitivity (IGT  20 mA) is also available. (IGT item: 1)
6. Make sure that your finished product containing this device meets your safe isolation requirements.
For safety, it's advisable that heatsink is electrically floating.
Test conditions
1. Junction temperature
Tj = 125/150C
2. Rate of decay of on-state commutating current
(di/dt)c = –10A/ms
3. Peak off-state voltage
VD = 400 V
Commutating voltage and current waveforms
(inductive load)
Supply Voltage
Main Current
Main Voltage
(dv/dt)c
Time
(di/dt)c
Time
Time
VD
R07DS0889EJ0100 Rev.1.00
Oct 29, 2012
Page 2 of 7