English
Language : 

BCR16FM14LB Datasheet, PDF (2/8 Pages) Renesas Technology Corp – Triac
BCR16FM-14LB
Preliminary
Electrical Characteristics
Parameter
Symbol
Rated value
Min. Typ. Max.
Unit
Test conditions
Repetitive peak off-state current
IDRM
—
—
2.0
mA Tj = 150°C, VDRM applied
On-state voltage
VTM
—
Gate trigger voltageNote2
Ι
VFGTΙ
—
ΙΙ
VRGTΙ
—
ΙΙΙ VRGTΙΙΙ
—
Gate trigger curentNote2
Ι
IFGTΙ
—
ΙΙ
IRGTΙ
—
ΙΙΙ
IRGTΙΙΙ
—
—
1.5
V
Tc = 25°C, ITM = 25A,
instantaneous measurement
—
1.5
—
1.5
V
Tj = 25°C, VD = 6 V, RL = 6 Ω,
V
RG = 330 Ω
—
1.5
V
—
30 Note5
mA Tj = 25°C, VD = 6 V, RL = 6 Ω,
—
30 Note5
mA RG = 330 Ω
—
30 Note5
mA
Gate non-trigger voltage
VGD
0.2
—
—
V
Tj = 125°C, VD = 1/2 VDRM
Thermal resistance
0.1
—
—
Tj = 150°C, VD = 1/2 VDRM
Rth (j-c)
—
—
2.9
°C/W Junction to caseNote3
Critical-rate of rise of off-state
(dv/dt)c 10
—
—
V/μs Tj = 125°C
commutation voltageNote4
1
—
—
Tj = 150°C
Notes: 1. Gate open.
2. Measurement using the gate trigger characteristics measurement circuit.
3. The contact themal resistance Rth (c-f) in case of greasing is 0.5°C /W.
4. Test conditions of the critical-rate of rise of off-state commutation voltage is shown in the table below.
5. High sensitivity (IGT≤20mA) is also available.(IGT item:1)
6. Make sure that your finished product containing this device meets your safe isolation requirements.
For safety, it's advisable that heatsink is electrically floating.
Test conditions
1. Junction temperature
Tj = 125/150°C
2. Rate of decay of on-state commutating current
(di/dt)c = –8.0A/ms
3. Peak off-state voltage
VD = 400 V
Commutating voltage and current waveforms
(inductive load)
Supply Voltage
Time
Main Current
Main Voltage
(dv/dt)c
(di/dt)c
Time
Time
VD
R07DS1189EJ0100 Rev.1.00
Mar 26, 2014
Page 2 of 7