English
Language : 

TLC59116 Datasheet, PDF (18/30 Pages) Texas Instruments – 16-CHANNEL Fm+ I2C-BUS CONSTANT-CURRENT LED SINK DRIVER
TLC59116
SLDS157B – FEBRUARY 2008 – REVISED JULY 2008 .................................................................................................................................................... www.ti.com
1.00
CM = 0 (Low Current Multiplier)
0.75
CM = 1 (High Current Multiplier)
HC = 0 (Low
HC = 1 (High
HC = 0 (Low
0.50 Voltage SubBand) Voltage SubBand) Voltage SubBand)
HC = 1 (High
Voltage SubBand)
0.25
0.00
Configuration Code (CM, HC, CC[0:5]) in Binary Format
Figure 9. Current Gain vs Configuration Code
Error Flags Registers (EFLAG1, EFLAG2)
Table 12 describes Error Flags Registers 1 and 2.
Table 12. EFLAG1, EFLAG2 – Error Flags Registers (Address 1Dh and 1Eh) Bit Description
ADDRESS REGISTER
BIT
SYMBOL ACCESS(1) VALUE(2)
DESCRIPTION (3)
1Dh
EFLAG1
7:0
EFLAG1[7:0]
R
1111 1111
Error flags 1. Upper 8-bit channel error
status.
1Eh
EFLAG2
7:0
EFLAG2[7:0]
R
1111 1111
Error flags 2. Lower 8-bit channel error
status.
(1) R = read, W = write
(2) Default value
(3) At power up, in order to initialize the Error Flags registers, the host must write 1 to bit 7 of the MODE2 register and then write 0 to bit 7
of the MODE2 register.
Open-Circuit Detection
The TLC59116 LED open-circuit detection compares the effective current level IOUT with the open load detection
threshold current IOUT,Th. If IOUT is below the threshold IOUT,Th the TLC59116 detects an open load condition. This
error status can be read out as an error flag through the registers EFLAG1 and EFLAG2.
For open-circuit error detection, a channel must be on.
Table 13. Open-Circuit Detection
STATE OF OUTPUT PORT
Off
On
CONDITION OF OUTPUT
CURRENT
IOUT = 0 mA
IOUT < IOUT,Th (1)
IOUT ≥ IOUT,Th (1)
ERROR STATUS CODE
0
0
Channel n error status bit 1
(1) IOUT,Th = 0.5 × IOUT,target (typical)
MEANING
Detection not possible
Open circuit
Normal
18
Submit Documentation Feedback
Copyright © 2008, Texas Instruments Incorporated