English
Language : 

RNA51957A_15 Datasheet, PDF (12/14 Pages) Renesas Technology Corp – Voltage Detecting, System Resetting IC Series
RNA51957A, B
Preliminary
Setting of Output Load Resistance (RNA51957B)
High level output voltage can be set without depending on the power-supply voltage because the output terminal is an
open collector type. However, please guard the following notes.
1. Please set it in value (2 V to 17 V) within the range of the power-supply voltage recommendation.
Moreover, please never impress the voltage of maximum ratings 18 V or more even momentarily either.
2. Please set output load resistance (pull-up resistance) RL so that the output current (output inflow current IL) at L
level may become 4 mA or less. Moreover, please never exceed absolute maximum rating (6 mA).
VCC (2 V to 17 V)
RL
6
IL ≤ 4mA
Figure 11 Output Load Resistance RL
Others
1. Notes when IC is handled are published in our reliability handbook, and please refer it.
The reliability handbook can be downloaded from our homepage (following URL).
http://www.renesas.com/products/common_info/reliability/index.jsp
2. Additionally, please inquire of our company when there is an uncertain point on use.
R03DS0010EJ0500 Rev.5.00
Jun 19, 2012
Page 12 of 13