We would like to inform you of the error correction and notes about receive processing of multi-buffer frame of Gigabit
Ethernet Controller.
1. Description of the RMSA0 bit is corrected
Page 858 of 1982
Description of the RMSA0 bit in the Receive/Relay Function Set Register (Port 0) (TSU_FWSL0) is corrected as follows.
[Error]
Sets the processing method when the SA (sourceaddress) of a frame received from port 0 is not registered in the entry table.
0: Frame is not received
1: Frame is received
[Correction]
Sets the processing method of a frame received from port 0.
0: Frame is received according to setup of the CAM function.
1: Frame is received regardless of setup of the CAM function.
2. Description of the RMSA1 bit is corrected
Page 860 of 1982
Description of the RMSA1 bit in the Receive/Relay Function Set Register (Port 1) (TSU_FWSL1) is corrected as follows.
[Error]
Sets the processing method when the SA (sourceaddress) of a frame received from port 1 is not registered in the entry table.
0: Frame is not received
1: Frame is received
[Correction]
Sets the processing method of a frame received from port 1.
0: Frame is received according to setup of the CAM function.
1: Frame is received regardless of setup of the CAM function.